Archived: LabVIEW 2011 Mobile Module Known Issues

Publish Date: Jul 22, 2018 | 1 Ratings | 5.00 out of 5 | Print

Overview

This document has been archived and is no longer updated by National Instruments.

This document contains the known issues that were discovered before and since the release of LabVIEW 2011 Mobile Module. Not every issue known to NI will appear on this list; it is intended to only show the severe and more common issues that can be encountered.

Each Issue appears as a row in the table and includes these fields:
  • Issue ID
  • Legacy ID - The issue's legacy ID from NI's deprecated bug reporting database (if applicable)
  • Issue Title
  • Problem Description
  • Workaround
  • Reported Version - the earliest version of LabVIEW the issue was reported in
  • Resolved Version - version the issue was resolved or was no longer applicable
  • Date Added - the date the issue was added to the document (not reported date)

Document Organization

The Known Issues Document displays the issues by issue category.

Known Issues by Category

Please refer to Developer Zone Article " LabVIEW Known Issues Categories Defined" for an explanation of the categories and what types of issues are in each category.

Contacting NI

You can contact us by phone, email, or the discussion forums. Visit the NI Website to contact us. If you are contacting NI in regards to a specific issue, be sure to reference the ID number given in this document. If you have feedback on this specific document, please contact NI on this NI Developer Zone post.

Known Issues by Category

The following items are known issues in LabVIEW 2011 Mobile Module Known Issues sorted by Category.

Building and Distributing LabVIEW Applications
218483 Timeouts on Event Structures are finite when running VI in debug mode on Windows CE targets
Example Programs
305709 DAQmx Base AI examples hang when used with the Mobile Module



ID Known Issue
Building and Distributing LabVIEW Applications
218483

Return
Timeouts on Event Structures are finite when running VI in debug mode on Windows CE targets
In order to enable debugging on a LabVIEW Mobile VI, timeouts are automatically reduced to a finite value even if they are originally set to infinite in the Block Diagram. This might change the functional behavior of the VI in Debug mode.

Workaround: N/A

Reported Version: 2010 32-bit    Resolved Version: N/A    Added: 05/14/2010
Example Programs
305709

Return
DAQmx Base AI examples hang when used with the Mobile Module
The DAQmx Base AI Examples hang when targeted to an archer Field PC with an ARM processor.

Workaround: N/A

Reported Version: 2011    Resolved Version: 2011 SP1    Added: 07/29/2011