OPC Device Connectivity
National Instruments has OPC Server software that is capable of communicating with a large number of PLCs, RTUs, and other industrial hardware. The software handles communication with the hardware and exposes every register or channel within the hardware as an OPC data item. These drivers were developed with 32-bit addressing for Windows 9x\NT\2000\ME\XP operating systems.
There are several different packages that can use the OPC Server software:
LabVIEW, LabWindows/CVI, Measurement Studio
These National Instruments software packages feature an OPC client. Use DataSocket functions to read and write to these OPC data items.
|
|
| With waveform data |
That requiring scaling |
| That need to record all of the data |
That require event driven architecture |
|
|
LabVIEW Datalogging and Supervisory Control (DSC) Module
The DSC Module is the ideal tool for your distributed monitoring applications and features an OPC server. Use the configuration-based Tag Engine to read and write to these OPC data items.
|
|
| With many hardware vendors | With waveform data |
| With integrated PLCs, DAQ, vision and motion | |
| Where network usage is a concern | |
| That need to scale | |
| That only need to record significant changes in the data, as defined by the user | |
|
|
Lookout
National Instruments Lookout features an OPC client. Use objects to read and write to these OPC data items.
|
|
| That need non-programming solutions | Requiring DAQ |
| | Requiring integrated vision and motion |
| | With waveform data |
|
|
OPC Servers
The following drivers can be purchased separately, in the Industrial Automation OPC Servers CD, for use with LabVIEW, the DSC Module, LabWindows/CVI, and Measurement Studio.
National Instruments FieldPoint
National Instruments FOUNDATION Fieldbus
National Instruments NI-DAQ (5.0 and later)
National Instruments OPC Client (works with any OPC Server)
National Instruments Profibus (works with PC1500PFB for Windows NT)
National Instruments Remote SCXI
National Instruments SCXI
Advantech PC-Multilab card, Model 711B
Allen-Bradley (PLC 2 /30 via DH+, serial, or direct DF1)
Allen-Bradley (PLC5 /10 /11 /12 /15 /20 /25 /30 /40 /40L /60 /60L /VME /80) via Ethernet, DH+, DF1, or KF2
Allen-Bradley (SLC 500, 5/01, 5/02, 5/03, 5/04) via DH+, KF2, DH485 with additional hardware, or DF1
Allen-Bradley KE/KF/Serial
Allen-Bradley 1784-KT (DH+ Direct)
Allen-Bradley 1784-KTX (DH+ Direct, DH485)
Allen-Bradley 1784-PCMK (DH+ Direct, DH485)
Allen-Bradley S-S 5136-SD
Allen-Bradley MicroLogix 1500 via DF serial
Applicom Interface Card
Aquatrol W1500
ASCII General-Purpose Serial
Cutler-Hammer D50, D300 Serial
CTI TCP/IP (for Siemens TI Series 500 PLCs)
Delta-Tau (PMAC Motion Controller)
DNP 3.0
Fisher ROC 364 via serial
GE Fanuc Versamax via Ethernet
GE Series 90 (90-30, 90-70) via SNPX or Ethernet
Fatek Facon (MA/MB/MC)
Hitachi CPU22-02HB and CPU22-02HC Serial
Hitachi EH-150 series devices via Ethernet or Serial
IDEC Controllers ( IDEC Micro3, Micro3c, and OpenNet)
IPASCII (TCP/IP or UDP Protocol)
Klockner-Moeller Sucoma (via Applicom PC1000)
Koyo PLC Direct (205, 405) DirectNet
Mailer for sending e-mail messages
Mitsubishi A-Series (serial communications modules)
Mitsubishi FX (FX-24MR) via serial
Modicon Modbus (Daniel Floating Point)
Modicon Modbus ASCII
Modicon Modbus ASCII Slave
Modicon Modbus Ethernet
Modicon Modbus Plus via ISA SA85 Card
Modicon Modbus RTU
Modicon Modbus RTU Slave
Motorola Modbus (for Moscad)
Omni Flowmeter via Modbus serial
Omron HostLink via Serial
Omron C20, C200, C500, C1000, C2000 via serial
Omron CQM via Serial
Omron CPM1 via Serial
Opto-22 Hostwords via Serial or Ethernet
Opto-22 Mistic via Serial
Opto-22 Optumux via Serial
Otic Fisher and Porter Data Link ( via Applicom PC1000)
Pager for Alphanumeric and Numeric Paging Systems
Philips PPC COMM (P8 Series) via Serial
Profibus DP (via SS-Tech 5136-PFB)
Profibus DP (via Applicom PCI-1500PFB)
Profibus FMS (via Applicom PCI-1500FB)
Profibus L2 via Applicom Card
Profibus Sinec L2 (via SS-Tech 5136-PFB)
RKC Serial for REX-F400, -F700, and -F900 PLCs
Saia Bus (Applicom PC1000)
Scan-Data (LMX, SMR, or M-System RTUs)
Schneider April 1000 PLCs Ethway (Applicom PC2000ETH)
Schneider April 1000 PLCs FipWay (Applicom PC2000ETH)
Schneider April 1000 PLCs Jbus (Applicom PC1000)
Siemens 3964 and 3964R via Serial
Siemens AS511 (via Applicom PC1000)
Siemens AS511 via Serial
Siemens Dynamic RTU
Siemens HMI Adapter for S7-300/400 via Serial with HMI adapter
Siemens MPI (via Applicom PCI-1500PFB)
Siemens PPI (via Applicom PC1000)
Siemens PPI (via Applicom PCI-1500PFB)
Siemens Profibus L2 (via Applicom PCI-1500PFB)
Siemens Sinec H1Ethernet (via Applicom PC2000ETH)
Siemens TI Direct (Series 500 PLCs)
Siemens TI Dynamic (8635 & 8640 RTUs)
Siemens TI H1 for Series 500 PLCs (requires additional Siemens hardware and software)
Siemens TI HostLink (205, 305, 405) via Serial
Siemens TI Modbus (305,405)
Siemens TI TIWAY (Host Adapter PC Board)
Siemens TI TIWAY (Unilink Host Adapter)
Siemens TI TIWAY 405
Siemens TI TIWAY Autoset 1500
Siemens TI TIWAY Facts 405
Sixnet IOMUX (requires additional Sixnet Software)
Sixnet Versamux RTUs
Sixnet Sixtrac I/O
Square D Serial (SCP1xx, SCP3xx-SCP7xx)
Square D SY/Link (SCP1xx, SCP3xx-SCP7xx)
Square D SY/ENET (Windows NT only)
TCP/IP -- Any Compliant Device via IPASCII driver
Telemecanique Ethway (via Applicom PC2000ETH)
Telemecanique Unitelway (via Applicom PC1000)
Tesco LIQ-4 via Serial
Tesco LIQ-5 via Serial
Texas Instruments 8635, 86400 and 8641
Toshiba EX100 Serial HostLink
Toshiba M-Series (M20, M40) via Serial HostLink
Toshiba T-Series (T1,T2,T3) via Serial HostLink
UDP -- Any Compliant Device via IPASCII
Wizdom Co-Processor Board (motion control)
Drivers Available Only in Lookout
Elwood Phoneducer via modem
OPC Client for 3rd. Party OPC Servers
Drivers only available in Lookout with the Hardware
NI DeviceNet
NI DeviceNet Explicit
NI FieldPoint Driver
NI FOUNDATION Fieldbus driver for NI Hardware only
OPC Client for FieldPoint OPC Server
OPC Client for NI Data Acquisition (DAQ) Hardware
Drivers Available from Alliance Program Members
DirectLogic Plus (AutomationDirect.com, tel. 1-800-633-0405)
HART (Cardiac, Inc., tel +47 3593 0600, fax +47 3593 0666, e-mail cardiac@cardiac.no)
IDEC (Aim Mgmt. Services., tel 954-987-5140)
Siemens S7 MPI (Gopel Elec., tel +49 3641 6896 0)
Uni-Telway (Saphir, tel +33 4 76 45 21 21)
If you do not see the driver that you need, please contact us.