Table Of Contents

IMAQdx Serial Read Bytes (G Dataflow)

Version:
    Last Modified: August 19, 2019

    Reads in an expected number of bytes from the serial port on image acquisition devices that support serial communication.

    connector_pane_image
    datatype_icon

    session in

    Unique reference to the camera, which you can obtain with the IMAQdx Initialize node.

    datatype_icon

    timeout

    Time, in milliseconds, to wait for the read to finish.

    datatype_icon

    bytes to read

    The number of bytes to read from the serial port.

    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    session out

    Unique reference to the camera. session out is the same as session in.

    datatype_icon

    data

    The array of bytes read from the serial port.

    datatype_icon

    bytes read

    The number of bytes stored in the byte array.

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: Not supported

    Web Server: Not supported in VIs that run in a web application