    User Setting User Command User Data 0 Value User Data 1 Value User Return Value
    Clock Settings 0 0 = Internal Sample Clock

    1 = Internal Sample Clock locked to an external Reference Clock through the CLK IN connector

    2 = External Sample Clock through the CLK IN connector (disables the CLK OUT connector)

    3 = Internal Sample Clock locked to an external Reference Clock through Sync Clock

    4 = External Sample Clock through the Sync Clock

    Default: 0 = 500 MHz DAC output clock, 1 GHz timebase, no interpolation.

    Refer to the User Data Clock Settings table for more information.

    N/A
    Read User EEPROM 6 EEPROM address to read data. N/A Read data.
    Write User EEPROM 7 EEPROM address to write data. Write data. N/A
    Reinitialize 0xFF N/A N/A N/A