    About These Specifications

    Specifications characterize the warranted performance of the instrument under the following operating conditions:

    • Chassis is powered on
    • Calibration adjustment cycle maintained
    • 50 Ω termination connected to unused I/O front panel connectors
    • Current product revision used

    Specifications describe the warranted, traceable product performance over ambient temperature ranges of 0 °C to 55°C unless otherwise noted.

    Typical values describe useful product performance beyond specifications that are not covered by warranty and do not include guardbands for measurement uncertainty or drift. Typical values may not be verified on all units shipped from the factory. Unless otherwise noted, typical values cover the expected performance of units over ambient temperature ranges of 23 °C ±5 °C with a 90% confidence interval.

    Nominal values (or supplemental information) describe additional information about the product that may be useful, including expected performance that is not covered under Typical Specifications. Nominal values are not covered by warranty.

    Input Characteristics

    All input characteristics are DC, ACrms, or a combination unless otherwise specified.

    Minimum input frequency

    10 MHz

    Maximum input frequency

    6 GHz

    Characteristic impedance (Z0)

    50 Ω, nominal

    Coupling

    AC

    Maximum safe DC input voltage

    ±5 V

    Maximum Safe Continuous RF Power

    Chassis Power ON Port:

    COM A, COM B, CH 0A, CH 0B

    +20 dBm

    CH 1A, CH 1B

    +20 dBm

    SUM AB

    +30 dBm

    Chassis Power OFF All Ports

    +20 dBm

    RF Performance Characteristics

    Values in parentheses are typical.

    Insertion loss, channel path
    COM A, COM B to SUM AB

    ≤850 MHz

    <13.1 dB (<11.8 dB)

    ≤1850 MHz

    <13.5 dB (<12.2 dB)

    ≤6 GHz

    <14.4 dB (<13.3 dB)

    COM A to CH 1A, COM B to CH 1B

    ≤850 MHz

    <2.3 dB (<1.2 dB)

    ≤1850 MHz

    <2.8 dB (<1.6 dB)

    ≤6 GHz

    <3.8 dB (<2.8 dB)

    COM A to CH 0A, COM B to CH 0B

    ≤850 MHz

    <2.2 dB (<1.1 dB)

    ≤1850 MHz

    <2.6 dB (<1.5 dB)

    ≤6 GHz

    <3.4 dB (<2.3 dB)

    COM A to COM B

    ≤850 MHz

    <3.3 dB (<2.0 dB)

    ≤1850 MHz

    <4.0 dB (<2.6 dB)

    ≤6 GHz

    <5.4 dB (<4.4 dB)

    Insertion loss

    a = 240 ppm/°C (thermal coefficient, typical)

    Use the following equation to calculate the insertion loss at a given temperature:

    I L T = I L T 0 ( 1 + α ( T T 0 ) )
    • where IL represents insertion loss in dB
    • T represents the temperature at which the property is being measured in °C
    • T0 represents the reference temperature in °C
    • a represents insertion loss temperature coefficient in ppm/°C
    Voltage standing wave ratio (VSWR), port
    SUM AB

    ≤850 MHz

    <1.3 (<1.1)

    ≤1850 MHz

    <1.4 (<1.1)

    ≤4 GHz

    <1.5 (<1.2)

    ≤6 GHz

    <1.7 (<1.2)

    CH 0A, CH 0B

    ≤850 MHz

    <1.5 (<1.2)

    ≤1850 MHz

    <1.5 (<1.2)

    ≤4 GHz

    <1.9 (<1.4)

    ≤6 GHz

    <1.9 (<1.4)

    CH 1A, CH 1B

    ≤850 MHz

    <1.5 (<1.2)

    ≤1850 MHz

    <1.5 (<1.2)

    ≤4 GHz

    <1.5 (<1.3)

    ≤6 GHz

    <2.2 (<1.6)

    COM A to COM B

    ≤850 MHz

    <1.5 (<1.3)

    ≤1850 MHz

    <1.7 (<1.3)

    ≤4 GHz

    <1.7 (<1.3)

    ≤6 GHz

    <1.9 (<1.6)

    Isolation
    COM A to COM B

    ≤850 MHz

    >19.6 dB (>20.6 dB)

    ≤1850 MHz

    >19.6 dB (>20.6 dB)

    ≤4 GHz

    >19.6 dB (>20.6 dB)

    ≤6 GHz

    >19.6 dB (>20.6 dB)

    CH 1A to SUM AB, CH 1B to SUM AB

    ≤850 MHz

    >77.0 dB (>82.0 dB)

    ≤1850 MHz

    >68.0 dB (>70.0 dB)

    ≤4 GHz

    >55.7 dB (>57.4 dB)

    ≤6 GHz

    >48.1 dB (>51.0 dB)

    CH 1A to CH 1B

    ≤850 MHz

    >79.0 dB (>100.0 dB)

    ≤1850 MHz

    >79.0 dB (>97.0 dB)

    ≤4 GHz

    >70.9 dB (>74.7 dB)

    ≤6 GHz

    >59.3 dB (>62.0 dB)

    Input 1 dB Compression

    Minimum

    >31 dBm

    Typical

    >33 dBm

    Figure 1. Typical Insertion Loss
    Figure 2. Typical VSWR (CH0x, CH1x, SUMAB)
    Figure 3. Typical VSWR (COMA, COMB)
    Figure 4. Typical Isolation

    Linearity

    Third-order intermodulation distortion (Input IP3 (IIP3))

    IP3 (input), typical

    +55 dBm

    spd-note-note
    Note  

    Measurements performed with two 10 dBm input tones = 1 MHz apart. This specification is based on both experimental and calculated data.

    Dynamic Characteristics

    Maximum switch operate time

    45 ms

    spd-note-note
    Note  

    Switch operate time is defined as the time from TRIG IN falling to 10% to when the output reaches 90% of final value.

    spd-note-note
    Note  

    Certain applications may require additional time for proper settling. For information about including additional settling time, refer to the NI Switches Help.

    Trigger Characteristics

    Input trigger

    Sources

    PXI trigger lines 0-7

    Minimum pulse width

    150 ns

    spd-note-note
    Note  

    The NI PXIe-2790 can recognize trigger pulse widths less than 150 ns by disabling digital filtering. For information about disabling digital filtering, refer to the NI Switches Help.

    Output trigger

    Destinations

    PXI trigger lines 0-7

    Pulse width

    Programmable (1 ms to 62 ms)

    Physical Characteristics

    Switch type

    FET

    Front panel connectors

    7 SMA jacks, female (I/O)

    PXIe power requirement

    0.9 W at 3.3 V, 0.6 W at 12 V

    Dimensions (L × W × H)

    3U, one slot, PXI/cPCI module 21.6 cm × 2.0 cm × 13.0 cm (8.5 × 0.8 × 5.1 in.)

    Weight

    394 g (13.9 oz)

    Environment

    Operating temperature

    0 °C to 55 °C

    Storage temperature

    -20 °C to 70 °C

    Relative humidity

    5% to 85%, noncondensing

    Pollution Degree

    2

    Maximum altitude

    2,000 m

    Indoor use only.

    Shock and Vibration

    Operational Shock

    30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC 60068-2-27. Test profile developed in accordance with MIL-PRF-28800F.)

    Random Vibration

    Operating

    5 Hz to 500 Hz, 0.3 Grms

    Nonoperating

    5 Hz to 500 Hz, 2.4 Grms (Tested in accordance with IEC 60068-2-64. Nonoperating test profile exceeds the requirements of MIL-PRF-28800F, Class 3.)

    Compliance and Certifications

    Safety

    This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:

    • IEC 61010-1, EN 61010-1
    • UL 61010-1, CSA 61010-1
    spd-note-note
    Note  

    For UL and other safety certifications, refer to the product label or the Online Product Certification section.

    Electromagnetic Compatibility

    This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:
    • EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
    • EN 55011 (CISPR 11): Group 1, Class A emissions
    • EN 55022 (CISPR 22): Class A emissions
    • EN 55024 (CISPR 24): Immunity
    • AS/NZS CISPR 11: Group 1, Class A emissions
    • AS/NZS CISPR 22: Class A emissions
    • FCC 47 CFR Part 15B: Class A emissions
    • ICES-001: Class A emissions
    spd-note-note
    Note  

    In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, and heavy-industrial locations. In Europe, Canada, Australia, and New Zealand (per CISPR 11), Class A equipment is intended for use only in heavy-industrial locations.

    spd-note-note
    Note  

    Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes.

    spd-note-note
    Note  

    For EMC declarations, certifications, and additional information, refer to the Online Product Certification section.

    CE Compliance

    This product meets the essential requirements of applicable European Directives, as follows:

    • 2014/35/EU; Low-Voltage Directive (safety)
    • 2014/30/EU; Electromagnetic Compatibility Directive (EMC)

    Online Product Certification

    Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column.

    Environmental Management

    NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.

    For additional environmental information, refer to the Minimize Our Environmental Impact web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document.

    Waste Electrical and Electronic Equipment (WEEE)
    spd-note-weee
    EU Customers  

    At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/environment/weee.

    电子信息产品污染控制管理办法(中国RoHS)
    spd-note-china-rohs
    中国客户  

    National Instruments符合中国电子信息产品中限制使用某些有害物质指令(RoHS)。关于National Instruments中国RoHS合规性信息,请登录 ni.com/environment/rohs_china。(For information about China RoHS compliance, go to ni.com/environment/rohs_china.)


    Recently Viewed Topics