Table Of Contents

PXI-5690 Specifications

Version:
    Last Modified: February 28, 2018

    Definitions

    Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

    The following characteristic specifications describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.

    • Typical specifications describe the performance met by a majority of models.
    • Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing.

    Specifications are Typical unless otherwise noted.

    Conditions

    Specifications are valid under the following conditions unless otherwise noted.

    • 15-minute warm-up time at 25 °C ambient temperature.
    • Calibration cycle maintained
    • 100 kHz to 3.0 GHz

    Frequency Range

    Frequency range

    100 kHz to 3.0 GHz

    Channels

    Number of channels

    2

    Gain

    Channel 0

    Fixed

    Channel 1

    Programmable

    Channel 0 (CH 0)

    Channel 0 (CH 0) Main Path

    Gain calibration accuracy

    ±0.4 dB[1]

    Gain variation by temperature

    Less than -0.03 dB/°C

    Maximum output power

    +20 dBm

    Output 1 dB compression

    +18 dBm, typical

    Second harmonic at +4 dBm

    -40 dBc, typical

    Survival input power

    -10 dBm, maximum

    DC voltage at input

    ±20 V, maximum[2]

    Channel 0 Performance

    Figure 1. Gain [3]
    Figure 2. Noise Figure (NF) [4]
    Figure 3. Input and Output Voltage Standing Wave Ratio (VSWR)
    Figure 4. Output Third Order Intercept (TOI) [5]
    Figure 5. Reverse Isolation

    Channel 1

    Channel 1 (CH 1) Main Path

    Gain calibration accuracy

    ±0.4 dB[6]

    Gain variation by temperature

    Less than -0.03 dB/°C

    Maximum output power

    +20 dBm

    Output 1 dB compression

    +16 dBm, typical

    Second harmonic at +4 dBm

    -40 dBc, typical

    Survival input power

    +20 dBm, maximum (with attenuation)

    DC voltage at input

    ±20 V, maximum[7]

    Channel 1 Performance, Main Path

    Figure 6. Programmable Gain Range [8]
    Figure 7. Noise Figure (NF) [9]
    Figure 8. Input and Output VSWR
    Figure 9. Output TOI [10]
    Figure 10. Reverse Isolation

    Channel 1 (CH 1) Direct Path

    Insertion loss calibration accuracy

    ±0.4 dB[11]

    Survival input power

    +20 dBm, maximum (with attenuation)

    DC voltage at input

    ±20 V, maximum[12]

    Channel 1 Performance, Direct Path

    Figure 11. Insertion Loss
    Figure 12. Input and Output VSWR

    Power Requirements

    Power Rail (VDC) Maximum Current (mA) Typical Current (mA)
    +3.3 150 110
    +5 0 0
    +12 350 300
    –12 10 3

    Calibration

    Interval

    1 year

    Physical Characteristics

    Front Panel Connectors

    CH 0 IN

    Connector

    SMA female

    Impedance

    50 Ω

    Coupling

    AC

    Input amplitude

    -10 dBm, maximum

    CH 0 OUT

    Connector

    SMA female

    Impedance

    50 Ω

    Output amplitude

    +20 dBm, maximum

    CH 1 IN

    Connector

    SMA female

    Impedance

    50 Ω

    Main path coupling

    AC [13]

    Input amplitude

    +20 dBm, maximum (with attenuation)[14]

    CH 1 OUT

    Connector

    SMA female

    Impedance

    50 Ω

    Output amplitude

    +20 dBm, maximum

    Physical Dimensions

    Dimensions

    3U, One Slot, PXI/cPCI Module 21.6 cm × 2.0 cm × 13.0 cm (8.5 in. × 0.8 in. × 5.1 in.)

    Weight

    263 g (9.2 oz)

    Environment

    Maximum altitude

    2,000 m (at 25 °C ambient temperature)

    Pollution Degree

    2

    Indoor use only.

    Operating Environment

    Ambient temperature range

    0 to 55 °C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2.)

    Relative humidity range

    10% to 90%, noncondensing (Tested in accordance with IEC 60068-2-56.)

    Storage Environment

    Ambient temperature range

    -40 °C to 70 °C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2.)

    Relative humidity range

    5% to 95%, noncondensing (Tested in accordance with IEC 60068-2-56.)

    Shock and Vibration

    Operational shock

    30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC 60068-2-27. Test profile developed in accordance with MIL-PRF-28800F.)

    Random vibration

    Operating

    5 Hz to 500 Hz, 0.3 grms

    Nonoperating

    5 Hz to 500 Hz, 2.4 grms (Tested in accordance with IEC 60068-2-64. Nonoperating test profile exceeds the requirements of MIL-PRF-28800F, Class 3.)

    Compliance and Certifications

    Safety

    This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:

    • IEC 61010-1, EN 61010-1
    • UL 61010-1, CSA C22.2 No. 61010-1
    spd-note-note
    Note  

    For UL and other safety certifications, refer to the product label or the Online Product Certification section.

    Electromagnetic Compatibility

    This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:
    • EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
    • EN 55011 (CISPR 11): Group 1, Class A emissions
    • AS/NZS CISPR 11: Group 1, Class A emissions
    • FCC 47 CFR Part 15B: Class A emissions
    • ICES-001: Class A emissions
    spd-note-note
    Note  

    In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, and heavy-industrial locations. In Europe, Canada, Australia, and New Zealand (per CISPR 11), Class A equipment is intended for use only in heavy-industrial locations.

    spd-note-note
    Note  

    Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes.

    spd-note-note
    Note  

    For EMC declarations, certifications, and additional information, refer to the Online Product Certification section.

    CE Compliance

    This product meets the essential requirements of applicable European Directives, as follows:

    • 2014/35/EU; Low-Voltage Directive (safety)
    • 2014/30/EU; Electromagnetic Compatibility Directive (EMC)

    Online Product Certification

    Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column.

    Environmental Management

    NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.

    For additional environmental information, refer to the Minimize Our Environmental Impact web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document.

    Waste Electrical and Electronic Equipment (WEEE)

    spd-note-weee
    EU Customers  

    At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/environment/weee.

    电子信息产品污染控制管理办法(中国RoHS)

    spd-note-china-rohs
    中国客户  

    National Instruments符合中国电子信息产品中限制使用某些有害物质指令(RoHS)。关于National Instruments中国RoHS合规性信息,请登录 ni.com/environment/rohs_china。(For information about China RoHS compliance, go to ni.com/environment/rohs_china.)

    • 1 Under 500 kHz, ±1.5 dB. For all frequencies, degrades by ±0.03 dB/°C outside by 15 °C to 35 °C temperature range.
    • 2 Nondamaging for steady-state DC only. Direct path passes input DC level to output.
    • 3 Typical flatness ±0.5 dB.
    • 4 For all frequencies, typical NF variation of ≤0.8 dB across entire operating temperature range.
    • 5 For all frequencies, typical TOI variation of ≤2.5 dB across entire operating temperature range.
    • 6 Under 500 kHz, ±1.5 dB. For all frequencies, degrades by ±0.03 dB/°C outside by 15 °C to 35 °C temperature range.
    • 7 Nondamaging for steady-state DC only. Direct path passes input DC level to output.
    • 8 Available in nominal 1 dB steps.
    • 9 For all frequencies, typical NF variation of ≤0.8 dB across entire operating temperature range.
    • 10 For all frequencies, typical TOI variation of ≤2.5 dB across entire operating temperature range.
    • 11 Under 500 kHz, ±1.5 dB. For all frequencies, degrades by ±0.03 dB/°C outside by 15 °C to 35 °C temperature range.
    • 12 Nondamaging for steady-state DC only. Direct path passes input DC level to output.
    • 13 Direct path passes input DC level to output.
    • 14 To achieve required level of attenuation, set gain to ≤15 dB for input frequencies ≤1.5 GHz or set gain to ≤10 dB for input frequencies >1.5 GHz .