Table Of Contents

PXI-2567 Specifications

Version:
    Last Modified: December 13, 2017

    spd-note-caution
    Caution  

    The protection provided by the PXI-2567 can be impaired if it is used in a manner not described in this document.

    Definitions

    Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

    The following characteristic specifications describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.

    • Typical specifications describe the performance met by a majority of models.
    • Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing.

    Specifications are Typical unless otherwise noted.

    Conditions

    Specifications are valid at 23 °C unless otherwise noted.

    All voltages are specified in DC, ACpk, or a combination unless otherwise specified.

    Topology

    Topology

    Independent

    Input[1]

    Maximum drive voltage, external power

    50 V DC

    Maximum drive current

    Per channel

    600 mA

    Per module

    25 A

    Internal drive power[2]

    5 V at 1.25 A

    12 V at 0.5 A

    Dynamic

    Single-channel operate time[3] [4]at 25 °C

    60 μs, typical

    Channel-to-ground resistance (RDSon)

    0 mA to 600 mA drive current

    0.280 Ω, maximum

    Channel off drain current (IDSS)

    13 V drive voltage

    50 μA, typical

    25 V drive voltage

    200 μA, typical

    Trigger

    Input trigger

    Sources

    PXI trigger lines <0...7>

    Minimum pulse width[5]

    150 ns

    Front panel/terminal block input voltage

    -0.5 V, minimum

    +0.7 V, VL maximum

    +2.0 V, VH minimum

    +3.3 V, nominal

    +5.5 V, maximum

    Output trigger

    Destinations

    PXI trigger lines <0...7>

    Pulse width

    Software-selectable: 1 μs to 62 μs

    Front panel voltage

    3.3 V TTL, 8 mA, nominal

    Physical

    I/O connector

    78-pin D-SUB

    PXI power requirement, including optional internal drive power

    5 V

    8 W

    3.3 V

    0.5 W

    12 V

    6 W

    Dimensions (L × W × H)

    3U, one slot, PXI/cPCI module

    21.6 × 2.0 × 13.0 cm (8.5 × 0.8 × 5.1 in.)

    Weight

    220 g (8 oz)

    Environment

    Operating temperature

    0 °C to 55 °C

    Storage temperature

    -20 °C to 70 °C

    Relative humidity

    5% to 85%, noncondensing

    Pollution Degree

    2

    Maximum altitude

    2,000 m

    Indoor use only.

    Shock and Vibration

    Operational Shock

    30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC 60068-2-27. Test profile developed in accordance with MIL-PRF-28800F.)

    Random Vibration

    Operating

    5 Hz to 500 Hz, 0.3 grms

    Nonoperating

    5 Hz to 500 Hz, 2.4 grms (Tested in accordance with IEC 60068-2-64. Nonoperating test profile exceeds the requirements of MIL-PRF-28800F, Class 3.)

    Compliance and Certifications

    Safety

    This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:

    • IEC 61010-1, EN 61010-1
    • UL 61010-1, CSA C22.2 No. 61010-1
    spd-note-note
    Note  

    For UL and other safety certifications, refer to the product label or the Online Product Certification section.

    Electromagnetic Compatibility

    This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:
    • EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
    • EN 55011 (CISPR 11): Group 1, Class A emissions
    • AS/NZS CISPR 11: Group 1, Class A emissions
    • FCC 47 CFR Part 15B: Class A emissions
    • ICES-001: Class A emissions
    spd-note-note
    Note  

    In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, and heavy-industrial locations. In Europe, Canada, Australia, and New Zealand (per CISPR 11), Class A equipment is intended for use only in heavy-industrial locations.

    spd-note-note
    Note  

    Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes.

    spd-note-note
    Note  

    For EMC declarations and certifications, refer to the Online Product Certification section.

    CE Compliance

    This product meets the essential requirements of applicable European Directives, as follows:

    • 2014/35/EU; Low-Voltage Directive (safety)
    • 2014/30/EU; Electromagnetic Compatibility Directive (EMC)

    Online Product Certification

    Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column.

    Environmental Management

    NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.

    For additional environmental information, refer to the Minimize Our Environmental Impact web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document.

    Waste Electrical and Electronic Equipment (WEEE)

    spd-note-weee
    EU Customers  

    At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/environment/weee.

    电子信息产品污染控制管理办法(中国RoHS)

    spd-note-china-rohs
    中国客户  

    National Instruments符合中国电子信息产品中限制使用某些有害物质指令(RoHS)。关于National Instruments中国RoHS合规性信息,请登录 ni.com/environment/rohs_china。(For information about China RoHS compliance, go to ni.com/environment/rohs_china.)

    • 1 Per channel protection circuitry includes overvoltage protection, which activates at 80 V, maximum; over-current protection, which activates at 1.5 A, minimum; and over-temperature which activates at 150 °C junction temperature.
    • 2 The 5 V and 12 V internal power supplies have fuses for over-current protection. These fuses are user replaceable.
    • 3 The operate time is measured from an input trigger to 90% activation of a 500 Ω resistor or between consecutive channel operations.
    • 4 During power-on or reset, all relay drivers disconnect (power down).
    • 5 The PXI-2567 can recognize trigger pulse widths less than 150 ns if you disable digital filtering. Refer to the NI Switches Help for information about disabling digital filtering.