Table Of Contents

PXI-6040 Pinout

Version:
    Last Modified: March 21, 2017

    Table 1. Signal Descriptions
    Signal Reference Description

    AI GND

    Analog Input Ground—These terminals are the reference point for single-ended AI measurements in RSE mode and the bias current return point for DIFF measurements. All ground references—AI GND, AO GND, and D GND—are connected on the device.

    AI <0..15>

    Varies

    Analog Input Channels For single-ended measurements, each signal is an analog input voltage channel. In RSE mode, AI GND is the reference for these signals. In NRSE mode, the reference for each AI signal is an AI SENSE.

    For differential measurements, AI 0 and AI 8 are the positive and negative inputs of differential analog input channel 0. Similarly, the following signal pairs also form differential input channels: AI <1,9>, AI <2,10>, and so on.

    AI SENSE

    Analog Input SenseIn NRSE mode, the reference for each AI <0..15> signal is AI SENSE.

    AO <0,1>

    AO GND

    Analog Output Channels—These terminals supply voltage output.

    AO GND

    Analog Output Ground—AO GND is the reference for AO. All ground references—AI GND, AO GND, and D GND—are connected on the device.

    D GND

    Digital GroundD GND supplies the reference for digital channels, PFI, and +5 V. All ground references—AI GND, AO GND, and D GND—are connected on the device.

    P0.<0..7>

    D GND

    Port 0 Digital I/O ChannelsYou can configure each signal individually as an input or output. P0.6 and P0.7 can also control the up/down signal of Counters 0 and 1, respectively.

    AO EXT REF

    D GND

    External Reference—This pin is the external reference input for the AO circuitry.

    +5 V

    D GND

    +5 V Power Source—These terminals supply a +5 V power source.

    AI HOLD COMP

    D GND

    AI Hold Complete Event Signal——When enabled, this signal pulses once for each A/D conversion in sample mode. The low-to-high edge indicates when the input signal can be removed from the input or switched to another signal.

    EXT STROBE

    D GND

    External Strobe Signal—Do not connect signals to this terminal.

    PFI 0/AI START TRIG

    D GND

    Programmable Function Interface or AI Start Trigger SignalAs an input, this terminal is a PFI. As an output, this pin is the ai/StartTrigger signal. In applications with pre-trigger samples, a low-to-high transition indicates the initiation of the pre-trigger samples.

    PFI 1/AI REF TRIG

    D GND

    Programmable Function Interface or AI Reference Trigger SignalAs an input, this terminal is a PFI. As an output, this terminal emits the AI Reference Trigger signal. In applications with pre-trigger samples, a low-to-high transition indicates the initiation of the pre-trigger samples. AI Reference Trigger is not used in applications with post-trigger samples.

    PFI 2/AI CONV CLK

    D GND

    Programmable Function Interface or AI Convert Clock SignalAs an input, this terminal is a PFI. As an output, this terminal is the AI Convert Clock signal. A high-to-low edge on AI CONV indicates that an A/D conversion is occurring.

    PFI 3/CTR 1 SOURCE

    D GND

    Programmable Function Interface or Counter 1 Source SignalAs an input, this terminal is a PFI. As an output, this terminal emits the selected Ctr1Source signal. This signal reflects the actual source signal connected to Counter 1.

    PFI 4/CTR 1 GATE

    D GND

    Programmable Function Interface or Counter 1 Gate SignalAs an input, this terminal is a PFI. As an output, this terminal emits the selected Ctr1Gate signal. This signal reflects the actual gate signal connected to Counter 1.

    PFI 5/AO SAMP CLK*

    D GND

    Programmable Function Interface or AO Sample Clock SignalAs an input, this terminal is a PFI. As an output, this terminal emits the AO Sample Clock signal. A high-to-low transition of this signal indicates that the AO primary group is being updated.

    PFI 6/AO START TRIG

    D GND

    Programmable Function Interface or AO Start Trigger SignalAs an input, this terminal is a PFI. As an output, this terminal emits the AO Start Trigger signal. In timed AO sequences, a low-to-high transition indicates the initiation of the waveform generation.

    PFI 7/AI SAMP CLK*

    D GND

    Programmable Function Interface or AI Sample Clock SignalAs an input, this terminal is a PFI. As an output, this terminal emits the AI Sample Clock signal. This terminal pulses once at the start of each AI sample in the interval sample. A high-to-low transition of this signal indicates the initiation of the waveform generation.

    PFI 8/CTR 0 SOURCE

    D GND

    Programmable Function Interface or Counter 0 Source SignalAs an input, this terminal is a PFI. As an output, this terminal emits the Ctr0Source signal. This signal reflects the actual source signal connected to Counter 0.

    PFI 9/CTR 0 GATE

    D GND

    Programmable Function Interface or Counter 0 Gate SignalAs an input, this terminal is a PFI. As an output, this terminal emits the Ctr0Gate signal. This signal reflects the actual gate signal connected to Counter 0.

    CTR 1 OUT

    D GND

    Counter 1 Output Signal—As an input, this terminal can be used to route signals directly to the RTSI bus. As an output, this terminal emits the Ctr1InternalOutput signal.

    CTR 0 OUT

    D GND

    Counter 0 Output Signal—As an input, this terminal can be used to route signals directly to the RTSI bus. As an output, this terminal emits the Ctr0InternalOutput signal.

    FREQ OUT

    D GND

    Frequency Output Signal—This output is from the frequency generator.