Table Of Contents

XNET Wait (CAN Remote Wakeup) (G Dataflow)

Version:
    Last Modified: February 22, 2017

    Waits for the CAN interface to wake up due to activity by a remote ECU on the network.

    connector_pane_image
    datatype_icon

    session in

    The session to apply the wait.

    datatype_icon

    timeout

    An input that specifies the maximum amount of time in seconds to wait.

    datatype_icon

    error in

    Error conditions that occur before this node runs. The node responds to this input according to standard error behavior.

    Default: No error

    datatype_icon

    session out

    An output that is the same as session in, provided for use with subsequent nodes.

    datatype_icon

    error out

    Error information. The node produces this output according to standard error behavior.

    Description

    This wait is used when you set the XNET Session Interface:CAN:Transceiver State property to Sleep. When asleep, the interface and transceiver go into a low-powered mode. If a remote CAN ECU transmits a frame, the transceiver detects this transmission, and both the controller and transceiver wake up. This wait detects that remote wakeup.

    spd-note-note
    Note  

    The interface neither receives nor acknowledges the transmission that caused the wakeup. However, after the interface wakes up, the transceiver automatically is placed into normal mode, and communication is restored.

    The timeout parameter provides the maximum number of seconds to wait. This value must be 1.0 (one second) or greater. The default value is 10 (10 seconds).