    Reads statistics for FlexRay communication using an XNET session.

    connector_pane_image
    datatype_icon

    session in

    The session to read. This session is selected from the LabVIEW project or returned from XNET Create Session.

    datatype_icon

    error in

    Error conditions that occur before this node runs. The node responds to this input according to standard error behavior.

    Default: No error

    datatype_icon

    session out

    An output that is the same as session in, provided for use with subsequent nodes.

    datatype_icon

    FlexRay statistics

    An output that returns a LabVIEW cluster that contains the statistical elements.

    datatype_icon

    num syntax error ch A

    The number of syntax errors that have occurred on channel A since communication started. A syntax error occurs if:

    • A node starts transmitting while the channel is not in the idle state.
    • There is a decoding error.
    • A frame is decoded in the symbol window or in the network idle time.
    • A symbol is decoded in the static segment, dynamic segment, or network idle time.
    • A frame is received within the slot after reception of a semantically correct frame (two frames in one slot).
    • Two or more symbols are received within the symbol window.
    datatype_icon

    num syntax error ch B

    The number of syntax errors that have occurred on channel B since communication started.

    datatype_icon

    num content error ch A

    The number of content errors that have occurred on channel A since communication started. A content error occurs if:

    • In a static segment, the payload length of a frame does not match the global cluster property.
    • In a static segment, the Startup indicator (bit) is 1 while the Sync indicator is 0.
    • A frame ID encoded in the frame header does not match the current slot.
    • A cycle count encoded in the frame’s header does not match the current cycle count.
    • In a dynamic segment, the Sync indicator is 1.
    • In a dynamic segment, the Startup indicator is 1.
    • In a dynamic segment, the Null indicator is 0.
    datatype_icon

    num content error ch B

    The number of content errors that have occurred on channel B since communication started.

    datatype_icon

    num slot boundary violation ch A

    The number of slot boundary violations that have occurred on channel A since communication started. A slot boundary violation error occurs if the interface does not consider the channel to be idle at the boundary of a slot (either beginning or end).

    datatype_icon

    num slot boundary violation ch B

    The number of slot boundary violations that have occurred on channel B since communication started.

    datatype_icon

    error out

    Error information. The node produces this output according to standard error behavior.

    Description

    You can use this XNET Read instance with any XNET session mode, as long as the session's interface is FlexRay. Because the state reflects the FlexRay interface, it can apply to multiple sessions.

    Like other XNET Read instances, this node executes quickly, so it is appropriate for real-time loops. The statistical information is updated during the Network Idle Time (NIT) of each FlexRay cycle.