Reads the Clk10 phase voltage value currently stored on the specified device's non-volatile onboard memory.

You can adjust this value using Adjust Clk10 Phase Voltage. Use this function in conjunction with the other NI-Sync external calibration functions to determine if the device needs an external calibration session.

spd-note-note
Note  
  • You do not need a calibration password to use this function. You can invoke this function with an instrument handle created with either Initialize (niSync) or Initialize External Calibration.
  • If you adjust the Clk10 phase voltage using Adjust Clk10 Phase Voltage as part of an open session, this function returns the new Clk10 phase voltage value you set using Adjust Clk10 Phase Voltage.
connector_pane_image
datatype_icon

instrument handle

The session handle that you obtain from Initialize or Initialize External Calibration.

datatype_icon

error in

Error conditions that occur before this node runs.

The node responds to this input according to standard error behavior.

Standard Error Behavior

Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

error in does not contain an error error in contains an error
If no error occurred before the node runs, the node begins execution normally.

If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

Default: No error

datatype_icon

instrument handle out

The session handle that you obtained from Initialize or Initialize External Calibration.

datatype_icon

error out

Error information.

The node produces this output according to standard error behavior.

Standard Error Behavior

Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

error in does not contain an error error in contains an error
If no error occurred before the node runs, the node begins execution normally.

If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.
datatype_icon

voltage

The current Clk10 phase voltage, in volts, stored on the device's non-volatile onboard memory.

Where This Node Can Run:

Desktop OS: Windows

FPGA: Not supported