Table Of Contents

Close (G Dataflow)

Last Modified: March 3, 2017

Terminates the NI-SWITCH session and all of its attributes and deallocates any memory resources the driver uses.

connector_pane_image
datatype_icon

session in

Control that identifies a particular NI-SWITCH session established with the niSwitch Initialize With Topology node, the niSwitch Initialize With Options node, or the niSwitch Initialize node.

datatype_icon

error in

Error conditions that occur before this node runs.

The node responds to this input according to standard error behavior.

Standard Error Behavior

Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

error in does not contain an error error in contains an error
If no error occurred before the node runs, the node begins execution normally.

If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

Default: No error

datatype_icon

error out

Error information.

The node produces this output according to standard error behavior.

Standard Error Behavior

Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

error in does not contain an error error in contains an error
If no error occurred before the node runs, the node begins execution normally.

If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

Re-initializing NI-SWITCH

After calling this node, you cannot use NI-SWITCH again until you call either the niSwitch Initialize With Topology node, the niSwitch Initialize With Options node, or the niSwitch Initialize node.

Closing with Errors

If error in describes an error that occurred before the call to niSwitch Close, this node still attempts to close the session. However, if the attempt fails, this node returns the error information that was passed in from error in.

Where This Node Can Run:

Desktop OS: Windows

FPGA: Not supported