Get Last Calibration Date (G Dataflow)

Version:
    Last Modified: April 2, 2018

    Returns the date of the last self-calibration, external calibration, or manufacturer calibration.

    connector_pane_image
    datatype_icon

    session in

    The instrument handle that you obtain from Initialize External Calibration. The handle identifies a particular instrument session.

    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    which date

    The calibration count to return, either self-calibration, external calibration, or manufacturer calibration.

    datatype_icon

    session out

    Reference to the NI-SCOPE instrument session to pass to the next node in the program.

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.
    datatype_icon

    year

    The year of the last calibration session.

    datatype_icon

    month

    The month of the last calibration (1 through 12).

    datatype_icon

    day

    The day of the last calibration session (1 through 31).

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: Not supported

    Web Server: Not supported in VIs that run in a web application