External Calibration

Version:
    Last Modified: March 2, 2017

    External calibration functions for NI-SCOPE.

    node_icon
    For the NI 5900 differential amplifier, this function calibrates the gain and offset.
    node_icon
    Externally calibrates the compensation attenuator.
    node_icon
    For NI 5105 digitizers, this function calibrates the external clock digital clock managers (DCMs).
    node_icon
    For the NI 5911, this function externally calibrates the internal reference.
    node_icon
    For the NI 5622, this function calibrates the frequency response of the device.
    node_icon
    For the NI 5102, this function externally calibrates a specified channel and vertical range.
    node_icon
    Externally calibrates the vertical offset.
    node_icon
    Externally calibrates the vertical range for the specified channel and vertical range setting.
    node_icon
    For SMC-based devices, this function calibrates the sample rate of the digitizer.
    node_icon
    Changes the password used to begin an external calibration session.
    node_icon
    Closes an external calibration session.
    node_icon
    Returns the number of times the digitizer has been calibrated.
    node_icon
    Returns the last self-calibration, external calibration, or manufacturer calibration date.
    node_icon
    Returns the value of the internal reference that is stored with Store Calibration Internal Reference during external calibration.
    node_icon
    Returns the miscellaneous information you can store during an external calibration session using Store Calibration Miscellaneous Info.
    node_icon
    Returns the onboard temperature, in degrees Celsius, of the digitizer at the time of the last self-calibration or external calibration.
    node_icon
    Takes an acquisition from a specified channel and retrieves the initial X value, which includes the time-to-digital conversion.
    node_icon
    For the NI 5112, this function routes the internal reference to the front BNC connector of the specified channel.
    node_icon
    For the NI 5900 differential amplifier, this function connects the specified channel to the calibration source and sets the calibration source to ±10 V or to GND.
    node_icon
    Opens an external calibration session handle that is required by all external calibration nodes..
    node_icon
    For the NI 5112, this function allows you to store the measured internal reference voltage value.
    node_icon
    Allows you to store miscellaneous information in the EEPROM of a device.