Table Of Contents

Configure Trigger Multimode Function (Analog » Edge) (G Dataflow)

Version:
    Last Modified: March 2, 2017

    Configures common properties for edge triggering.

    When you initiate an acquisition, the digitizer waits for the start trigger, which is configured through the Trigger Source property. The default is immediate. Upon receiving the start trigger, the digitizer begins sampling pre-trigger points. After the digitizer finished sampling pre-trigger points, the digitizer waits for a reference trigger. Upon receiving the reference trigger, the digitizer finishes the acquisition after completing post-trigger sampling.

    spd-note-note
    Note  
    • You can adjust the amount of pre-trigger and post-trigger samples using reference position of Configure Horizontal Timing. The default is half the record length.
    • Some features are not supported by all digitizers.
    connector_pane_image
    datatype_icon

    session out

    Identifies a particular instrument session.

    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    trigger source

    The source you want the digitizer to monitor for a trigger.

    Name Description
    Channel 0 Monitors Channel 0 for a trigger signal.
    Channel 1 Monitors Channel 1 for a trigger signal.
    Channel 2 Monitors Channel 2 for a trigger signal.
    Channel 3 Monitors Channel 3 for a trigger signal.
    Channel 4 Monitors Channel 4 for a trigger signal.
    Channel 5 Monitors Channel 5 for a trigger signal.
    Channel 6 Monitors Channel 6 for a trigger signal.
    Channel 7 Monitors Channel 7 for a trigger signal.
    External TRIG Monitors an external trigger input for a trigger signal.

    Default: Channel 0

    datatype_icon

    trigger level

    The voltage threshold for the trigger.

    Default: 0.00

    datatype_icon

    trigger slope

    The trigger edge on which to trigger the digitizer.

    datatype_icon

    trigger coupling

    The method used to couple the trigger signal.

    Name Value Description
    AC 0 Couples the trigger signal with an AC current.
    DC 1 Couples the trigger signal with a DC current.
    HF Reject 3 Couples the trigger signal with a high frequency reject filter.
    LF Reject 4 Couples the trigger signal with a low frequency reject filter.
    AC Plus HF Reject 1001 Couples the trigger signal with an AC current and a high frequency reject filter.

    Default: DC

    datatype_icon

    trigger holdoff

    The length of time the digitizer waits after detecting a trigger before enabling NI-SCOPE to detect another trigger.

    Default: 0.00

    datatype_icon

    trigger delay

    The length of time the digitizer waits after it receives the trigger to start acquiring data.

    datatype_icon

    session out

    Passes the instrument handle to the next node in the program. This parameter has the same value as session in.

    datatype_icon

    error out

    error out contains error information. This output provides standard error out functionality.

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: Not supported


    Recently Viewed Topics