Table Of Contents

Reset (G Dataflow)

Version:
    Last Modified: September 27, 2017

    Resets the session to its initial state. All channels and front panel terminals are put into a high-impedance state. All software attributes are reset to their initial values.

    All channels and front panel terminals are put into a high-impedance state. All software attributes are reset to their initial values.

    During a reset, signal routes between this and other devices are released, regardless of which device created the route. For instance, a trigger signal being exported to a PXI trigger line and used by another device is no longer exported.

    connector_pane_image
    datatype_icon

    session in

    Instrument session obtained from the Initialize Acquisition Session node, the Initialize Generation Session node, or the Initialize External Calibration node.

    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    session out

    Handle that identifies the session in all subsequent node calls.

    The session out parameter is obtained from the Initialize Acquisition Session node or the Initialize Generation Session node.

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Using the Reset Device node

    The Reset Device node is applied to the entire device. If you have both a generation and an acquisition session active, the Reset Device node resets the current session, including attributes, and invalidates the other session if it is committed or running. The other session must be closed.

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: Not supported

    Web Server: Not supported in VIs that run in a web application


    Recently Viewed Topics