Fetch (Fetch Waveform (1D U16)) (G Dataflow)

Version:
    Last Modified: September 27, 2017

    Fetches the data as an array of unsigned 16-bit integers and returns the number of samples read.

    connector_pane_image
    datatype_icon

    session in

    Instrument session obtained from the Initialize Acquisition Session node, the Initialize Generation Session node, or the Initialize External Calibration node.

    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    samples to read

    The specified number of samples to fetch.

    If you specify a value for samples to read that is greater than the number of samples in the device memory, NI-HSDIO returns the samples that are acquired after max time milliseconds. Setting this parameter to -1 acquires the samples per record specified in the niHSDIO Configure Acquisition Size node.

    datatype_icon

    maximum time (ms)

    The time, in milliseconds, allotted for the node to complete before NI-HSDIO returns a timeout error.

    If you set the value to -1, the node never times out. If you set this parameter to 0, the node returns immediately with up to the number of samples specified in samples to read.

    If samples to read is greater than the number of samples in the device memory and all the available samples are acquired before a timeout, NI-HSDIO returns the available samples.

    Default: 10000

    datatype_icon

    record to fetch

    Parameter that specifies which record you want to fetch from onboard memory.

    datatype_icon

    session out

    Handle that identifies the session in all subsequent node calls.

    The session out parameter is obtained from the Initialize Acquisition Session node or the Initialize Generation Session node.

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.
    datatype_icon

    data

    Parameter that returns the data for the waveform.

    datatype_icon

    number of samples read

    The number of samples that were successfully acquired and transferred into data.