Table Of Contents

Configure Initial State (Configure Initial State (U32)) (G Dataflow)

Version:
    Last Modified: September 27, 2017

    Sets the Initial state for a dynamic generation operation using a binary format.

    The Initial state of each channel is driven after the operation is initiated using the Initiate node. Channels remain unchanged until the operation is initiated. The Initial state is active after the session is initiated and until the start trigger generates the first waveform sample.

    connector_pane_image
    datatype_icon

    session in

    Instrument session obtained from the Initialize Acquisition Session node, the Initialize Generation Session node, or the Initialize External Calibration node.

    datatype_icon

    initial state

    The initial state of a dynamic generation operation.

    This parameter defines the bit mask representing the initial state. High is specified with a 1, and low is specified with a 0. If you need to specify values other than high and low, use the niHSDIO Configure Initial State (String) instance of this node.

    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    session out

    Handle that identifies the session in all subsequent node calls.

    The session out parameter is obtained from the Initialize Acquisition Session node or the Initialize Generation Session node.

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Where This Node Can Run: