Performs the open cable compensation measurements for the current capacitance/inductance range, and returns open cable compensation conductance and susceptance values.

This node returns an error if the value of the Function property is not set to CAPACITANCE or INDUCTANCE. You can use the return values of this node as inputs to Configure Open Cable Compensation Values.

connector_pane_image
datatype_icon

session in

Instrument identifier from previous NI-DMM nodes.

Default: None

datatype_icon

error in

Error conditions that occur before this node runs.

The node responds to this input according to standard error behavior.

Standard Error Behavior

Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

error in does not contain an error error in contains an error
If no error occurred before the node runs, the node begins execution normally.

If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

Default: No error

datatype_icon

session out

Instrument identifier for subsequent NI-DMM nodes.

datatype_icon

conductance

Measured value of open cable compensation conductance.

datatype_icon

susceptance

Measured value of open cable compensation susceptance.

datatype_icon

error out

Error information.

The node produces this output according to standard error behavior.

Standard Error Behavior

Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

error in does not contain an error error in contains an error
If no error occurred before the node runs, the node begins execution normally.

If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

Where This Node Can Run:

Desktop OS: Windows

FPGA: Not supported

Web Server: Not supported in VIs that run in a web application

Hardware Support:

This node is only supported for the PXI-4072 and PXIe-4082.