Table Of Contents

Set Calibration User Defined Info (G Dataflow)

Version:
Last Modified: September 16, 2017

Stores user-defined information in the EEPROM.

Use Get Calibration User Defined Info Maximum Size to see the maximum allowed string size.

connector_pane_image
datatype_icon

session in

Instrument identifier from previous NI-DMM nodes.

Default: None

datatype_icon

info

Custom information to be stored in the EEPROM.

datatype_icon

error in

Error conditions that occur before this node runs.

The node responds to this input according to standard error behavior.

Standard Error Behavior

Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

error in does not contain an error error in contains an error
If no error occurred before the node runs, the node begins execution normally.

If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

Default: No error

datatype_icon

session out

Instrument identifier for subsequent NI-DMM nodes.

datatype_icon

error out

Error information.

The node produces this output according to standard error behavior.

Standard Error Behavior

Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

error in does not contain an error error in contains an error
If no error occurred before the node runs, the node begins execution normally.

If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

Exceeding Maximum String Size

If the Info string size is larger than the maximum string size, NI-DMM stores as much of the information as possible, truncates the remainder, and returns a warning.

Examples

Use this node to store information that could be useful for future calibrations, such as the name of the person who performed the calibration or specifics about the calibration system.

Where This Node Can Run:

Desktop OS: Windows

FPGA: Not supported

Web Server: Not supported in VIs that run in a web application


Recently Viewed Topics