Table Of Contents

Sort Results (Sort Site Results (U32 Waveform)) (G Dataflow)

Version:
    Last Modified: September 14, 2017

    Orders site data read from multiple instruments to match the site list you specify and combines data from instruments mapped to the same site.

    To use this node, read data from each instrument using the same site list parameter and combine the data in a three-dimensional array. Each instrument returns data only for the sites on which the instrument is configured to capture waveforms.

    Pass the data array and the same site list as parameters to this node. The node returns sorted waveforms in the same order as values read using the niDigital Fetch Capture Waveform (U32) node.

    connector_pane_image
    datatype_icon

    sessions in

    Instrument sessions obtained from the niDigital Initialize with Options node.

    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    site list

    A comma-delimited list of strings of form siteN, where N is the site number. The sites you specify are enabled for pattern bursting. If you specify an empty string, the pattern is burst on all sites.

    datatype_icon

    waveforms

    The waveform data read from the digital pattern instruments, combined into a three-dimensional array.

    datatype_icon

    site result type

    The type of data specified in the results array.

    datatype_icon

    sorted waveforms

    The data in the results array sorted by the order in the site list, along with the site number that corresponds to each value..

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.
    datatype_icon

    sessions out

    Handle that identifies the sessions in all subsequent NI-Digital node calls.

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: Not supported

    Web Server: Not supported in VIs that run in a web application