Table Of Contents

Get Site Pass Fail (G Dataflow)

Version:
    Last Modified: September 14, 2017

    Returns the pass or fail results for each site.

    connector_pane_image
    datatype_icon

    session in

    Instrument session obtained from the niDigital Initialize with Options node.

    datatype_icon

    site list

    A comma-delimited list of strings in the form of siteN , where N is the site number to include in the list of pattern burst sites.

    If the string is empty, all sites are configured for pattern bursting.

    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    session out

    Handle that identifies the session in all subsequent NI-Digital node calls.

    datatype_icon

    pass

    The returned array of pass (True) and fail results for the sites you specify in the site list parameter.

    If sites span multiple digital pattern instruments, you must use an AND operator for the partial results for those sites returned by each instrument. If a site is disabled or not enabled for burst, the node does not return data for that site.

    Use the niDigital Sort Site Results (Boolean) node to order and combine the data to match the site list. You can also use the niDigital Get Site Results Site Numbers node to obtain a sorted list of returned sites.

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: Not supported

    Web Server: Not supported in VIs that run in a web application


    Recently Viewed Topics