Table Of Contents

Fetch Capture Waveform (U32) (G Dataflow)

Version:
Last Modified: September 14, 2017

Fetches a defined number of samples for a specific list of sites.

This node only returns data from sites that are enabled when fetch is called.

connector_pane_image
datatype_icon

waveform name

Waveform name you create with the niDigital Create Capture Waveform node.

Use the waveform name parameter with capture_start opcode in your pattern.

datatype_icon

session in

Instrument session obtained from the niDigital Initialize with Options node.

datatype_icon

site list

Site numbers listed as a comma-delimited list of strings of form siteN, where N is the site number.

If you enter an empty string, the node fetches data from all sites.

datatype_icon

timeout

Maximum time (in seconds) allowed for this node to complete.

If this node does not complete within this time interval, this node returns an error.

Default: 10 s

datatype_icon

samples to read

Number of samples to fetch.

datatype_icon

error in

Error conditions that occur before this node runs.

The node responds to this input according to standard error behavior.

Standard Error Behavior

Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

error in does not contain an error error in contains an error
If no error occurred before the node runs, the node begins execution normally.

If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

Default: No error

datatype_icon

session out

Handle that identifies the session in all subsequent NI-Digital node calls.

datatype_icon

data

A 2D array of digital states read from the sites in the site list.

Each row in the 2D array corresponds to a site in the list. If a site is disabled, not enabled for burst, or the current instrument does not include any capture pins, the node does not return data for that site.

Use the niDigital Sort Site Results (U32 Waveform) node to order and combine the data to match the site list. You can also use the niDigital Get Site Results Site Numbers node to obtain a sorted list of returned sites.

datatype_icon

error out

Error information.

The node produces this output according to standard error behavior.

Standard Error Behavior

Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

error in does not contain an error error in contains an error
If no error occurred before the node runs, the node begins execution normally.

If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

Where This Node Can Run:

Desktop OS: Windows

FPGA: Not supported

Web Server: Not supported in VIs that run in a web application