Table Of Contents

Disable Sites (G Dataflow)

Version:
    Last Modified: September 14, 2017

    Disables specified sites.

    Disabled sites are not included in pattern bursts initiated by the Initiate node or the Burst Pattern node, even if the site is specified in the list of pattern burst sites in Configure Pattern Burst Sites node or in the site list input of the Burst Pattern node.

    Additionally, if you specify a list of pin or pin group names in a channel list parameter in any NI-Digital node, digital pattern instrument channels mapped to disabled sites are not affected by the node. Nodes that return per-pin data, such as the PPMU Measure node, do not return data for channels mapped to disabled sites.

    The digital pattern instrument channels mapped to the sites specified are left in their current state.

    connector_pane_image
    datatype_icon

    session in

    Instrument session obtained from the niDigital Initialize with Options node.

    datatype_icon

    site list

    Comma-delimited list of strings in the form of siteN , where N is the site number. If you enter an empty string, the node enables all sites.

    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    session out

    Handle that identifies the session in all subsequent NI-Digital node calls.

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Compatibility with NI TestStand Semiconductor Module

    NI TestStand Semiconductor Module requires all sites to always be enabled, and manages the set of active sites without disabling the sites in the digital instrument session. Do not use this node with the Semiconductor Module.

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: Not supported

    Web Server: Not supported in VIs that run in a web application