Configure Pulse Current Level Range (G Dataflow)

Last Modified: January 29, 2018

Configures a range defining valid values that pulse current level and pulse bias current level can be set to for the specified channel(s).

The pulse current level range setting is applicable only if the output function of the channel is set to Pulse Current.

connector_pane_image
datatype_icon

session in

Instrument session obtained from the Initialize With Channels node.

datatype_icon

channel name

Output channel(s) to which to apply this configuration value.

Channel Name Syntax

You can input the channel name with the following options:
  • A single channel, such a 0
  • A list of channels, such as 0,1 or 3,2,1,0.
  • A range of channels, such as 0-7 or 0:7.
spd-note-note
Note  

The order of channels in a list is important. NI-DCPower performs configurations of multiple output channels in the order the channels occur in the list.

datatype_icon

pulse current level range

Range defining valid values, in amps, that pulse current level can be set to on the specified channel(s).

For valid ranges, refer to specifications for the device.

datatype_icon

error in

Error conditions that occur before this node runs.

The node responds to this input according to standard error behavior.

Standard Error Behavior

Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

error in does not contain an error error in contains an error
If no error occurred before the node runs, the node begins execution normally.

If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

Default: No error

datatype_icon

session out

Handle used to identify the session in all subsequent NI-DCPower node calls.

datatype_icon

error out

Error information.

The node produces this output according to standard error behavior.

Standard Error Behavior

Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

error in does not contain an error error in contains an error
If no error occurred before the node runs, the node begins execution normally.

If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

Setting the Output Function of the Channel

Use the Configure Output Function node to set the output function of the channel. The pulse current level range configured with the Configure Pulse Current Level Range node is applicable only if the channel is set to the Pulse Current output function.

Setting Pulse Current Level and Pulse Bias Current Level

Use the Configure Pulse Current Level node and the Configure Pulse Bias Current Level node to set pulse current level and pulse bias current level respectively.

Range Considerations

Selecting a range sets the resolution and the magnitude of the power supply or SMU output or measurement. A smaller range provides higher resolution and lower magnitude. A larger range provides lower resolution and higher magnitude.

Changing Ranges

When you configure an output range, if you request a range that differs from the ranges described in the device specifications, NI-DCPower selects the smallest range (highest resolution) available that accommodates the requested range. For example, on a device with only 20 mA and 200 mA current limit ranges, if you request 100 mA for the current range, NI-DCPower selects the 200 mA range.

To change the range, the configured range must be able to accommodate the configured output value. For example, if the current limit range is 1 A and the current limit is 50 mA, changing the current limit range to 20 mA is not allowed because 50 mA is not possible in the new range.

When changing ranges in the Running state, be aware of the order of the output range and output value changes because the configuration change takes effect immediately in this state. To avoid ordering issues, NI recommends that you configure the output range and output value in the Uncommitted state and then transition to the Running state. Alternatively, you can enable autoranging for the range you want to change.

Where This Node Can Run:

Desktop OS: Windows

FPGA: Not supported

Web Server: Not supported in VIs that run in a web application

Hardware Support:

This node supports the following hardware:

  • PXIe-4135
  • PXIe-4136/4137
  • PXIe-4138/4139