Configures the pulse voltage limit that the output must not exceed when generating the desired pulse current level for the specified channel(s).
The pulse voltage limit setting is only applicable if the output function of the channel is set to Pulse Current. The channel must be enabled for the specified voltage limit to take effect.
Instrument session obtained from the Initialize With Channels node.
Pulse voltage limit, in volts, that the output must not exceed when generating the desired pulse current level for the specified channel(s).
The limit is specified as a positive value, but symmetric positive and negative limits are enforced simultaneously.
Error conditions that occur before this node runs.
The node responds to this input according to standard error behavior.
Standard Error Behavior
Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.
Default: No error
Handle used to identify the session in all subsequent NI-DCPower node calls.
Error information.
The node produces this output according to standard error behavior.
Standard Error Behavior
Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.
Where This Node Can Run:
Desktop OS: Windows
FPGA: Not supported
Web Server: Not supported in VIs that run in a web application
Hardware Support:
This node supports the following hardware: