Creates an empty advanced sequence.
You must set the source mode to Sequence to use this node. Use this node in the Uncommitted or Committed programming states.
Using Advanced Sequence nodes with the Set Sequence node is unsupported.
Properties you reconfigure per step in the advanced sequence.
Supported Properties for Advanced Sequence Per Device
The following table lists which properties can be configured in an advanced sequence for each NI-DCPower device that supports advanced sequencing. A ✓ indicates that the property can be configured in advanced sequencing. An ✕ indicates that the property cannot be configured in advanced sequencing.
Property | PXIe-4135 | PXIe-4136 | PXIe-4137 | PXIe-4138 | PXIe-4139 | PXIe-4140/4142/4144 | PXIe-4141/4143/4145 |
---|---|---|---|---|---|---|---|
Measurement:Advanced:DC Noise Rejection | ✓ | ✕ | ✓ | ✕ | ✓ | ✕ | ✕ |
Measurement:Aperture Time | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Measurement:Measure Record Length | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Measurement:Sense | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Source:Advanced:OVP Enabled | ✓ | ✓ | ✓ | ✕ | ✕ | ✕ | ✕ |
Source:Advanced:OVP Limit | ✓ | ✓ | ✓ | ✕ | ✕ | ✕ | ✕ |
Source:Advanced:Pulse Bias Delay | ✓ | ✓ | ✓ | ✓ | ✓ | ✕ | ✕ |
Source:Advanced:Pulse Off Time | ✓ | ✓ | ✓ | ✓ | ✓ | ✕ | ✕ |
Source:Advanced:Pulse On Time | ✓ | ✓ | ✓ | ✓ | ✓ | ✕ | ✕ |
Source:Advanced:Source Delay | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Source:Custom Transient Response:Current:Compensation Frequency | ✓ | ✕ | ✓ | ✕ | ✓ | ✕ | ✓ |
Source:Custom Transient Response:Current:Gain Bandwidth | ✓ | ✕ | ✓ | ✕ | ✓ | ✕ | ✓ |
Source:Custom Transient Response:Current:Pole-Zero Ratio | ✓ | ✕ | ✓ | ✕ | ✓ | ✕ | ✓ |
Source:Custom Transient Response:Voltage:Compensation Frequency | ✓ | ✕ | ✓ | ✕ | ✓ | ✕ | ✓ |
Source:Custom Transient Response:Voltage:Gain Bandwidth | ✓ | ✕ | ✓ | ✕ | ✓ | ✕ | ✓ |
Source:Custom Transient Response:Voltage:Pole-Zero Ratio | ✓ | ✕ | ✓ | ✕ | ✓ | ✕ | ✓ |
Source:DC Current:Current Level | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Source:DC Current:Current Level Range | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Source:DC Current:Voltage Limit | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Source:DC Current:Voltage Limit Range | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Source:DC Voltage:Current Limit | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Source:DC Voltage:Current Limit Range | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Source:DC Voltage:Voltage Level Range | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Source:Output Enabled | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Source:Output Function | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Source:Output Resistance | ✓ | ✕ | ✓ | ✕ | ✓ | ✕ | ✓ |
Source:Pulse Current:Pulse Bias Current Level | ✓ | ✓ | ✓ | ✓ | ✓ | ✕ | ✕ |
Source:Pulse Current:Pulse Bias Voltage Limit | ✓ | ✓ | ✓ | ✓ | ✓ | ✕ | ✕ |
Source:Pulse Current:Pulse Current Level | ✓ | ✓ | ✓ | ✓ | ✓ | ✕ | ✕ |
Source:Pulse Current:Pulse Current Level Range | ✓ | ✓ | ✓ | ✓ | ✓ | ✕ | ✕ |
Source:Pulse Current:Pulse Voltage Limit | ✓ | ✓ | ✓ | ✓ | ✓ | ✕ | ✕ |
Source:Pulse Current:Pulse Voltage Limit Range | ✓ | ✓ | ✓ | ✓ | ✓ | ✕ | ✕ |
Source:Pulse Voltage:Pulse Bias Current Limit | ✓ | ✓ | ✓ | ✓ | ✓ | ✕ | ✕ |
Source:Pulse Voltage:Pulse Bias Voltage Level | ✓ | ✓ | ✓ | ✓ | ✓ | ✕ | ✕ |
Source:Pulse Voltage:Pulse Current Limit | ✓ | ✓ | ✓ | ✓ | ✓ | ✕ | ✕ |
Source:Pulse Voltage:Pulse Current Limit Range | ✓ | ✓ | ✓ | ✓ | ✓ | ✕ | ✕ |
Source:Pulse Voltage:Pulse Voltage Level | ✓ | ✓ | ✓ | ✓ | ✓ | ✕ | ✕ |
Source:Pulse Voltage:Pulse Voltage Level Range | ✓ | ✓ | ✓ | ✓ | ✓ | ✕ | ✕ |
Source:Transient Response | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Instrument session obtained from the Initialize With Channels node.
Name of the sequence to create.
Error conditions that occur before this node runs.
The node responds to this input according to standard error behavior.
Standard Error Behavior
Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.
Default: No error
Handle used to identify the session in all subsequent NI-DCPower node calls.
Error information.
The node produces this output according to standard error behavior.
Standard Error Behavior
Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.
Use advanced sequencing instead of Sequence source mode when you want more options for configuring the device in each step of the sequence.
Call the Create Advanced Sequence Step node to add steps to the active advanced sequence.
Where This Node Can Run:
Desktop OS: Windows
FPGA: Not supported
Hardware Support:
This node does not support the following devices: