Table Of Contents

DAQmx Create TEDS Virtual Channel (DAQmx Create Channel (TEDS-AI-Current-Basic)) (G Dataflow)

Last Modified: September 18, 2017

Creates channel(s) to measure current. You must configure the physical channel(s) with TEDS information to use this VI.

connector_pane_image
datatype_icon

task in

task in specifies the task to which to add the virtual channels this node creates. If you do not specify a task, NI-DAQmx creates a task for you, and adds the virtual channels this node creates to that task.

datatype_icon

physical channels

physical channels specifies the names of the physical channels to use to create virtual channels. The DAQmx physical channel constant lists all physical channels on devices and modules installed in the system.

You can also wire a string that contains a list, or range of physical channels, to this input. If you have an array of physical channels, use the DAQmx Flatten Channel String node to convert the array to a list.

datatype_icon

name to assign

name to assign specifies a name to assign to the virtual channel this node creates. If you do not wire a value to this input, NI-DAQmx uses the physical channel name as the virtual channel name.

If you use this input to provide your own names for the virtual channels, you must use the names when you refer to these channels in other NI-DAQmx nodes, such as the source input of the DAQmx Trigger node.

If you create multiple virtual channels with one DAQmx Create Virtual Channel node, you can specify a comma-separated list of names to assign to the virtual channels. If you provide fewer names than the number of virtual channels you create, NI-DAQmx automatically assigns names to the virtual channels.

datatype_icon

units

units specifies the units to use to return measurements.

Name Description
From Custom Scale

Units a custom scale specifies. If you select this value, you must wire a custom scale name to the custom scale name input.

From TEDS

Units defined by TEDS information associated with the channel.

datatype_icon

error in

error in describes error conditions that occur before this node runs. This input provides standard 'error in' functionality.

datatype_icon

measurement range

measurement range specifies the minimum and maximum values you expect to measure.

datatype_icon

maximum value

maximum value specifies in units the maximum value you expect to measure.

datatype_icon

minimum value

minimum value specifies in units the minimum value you expect to measure.

datatype_icon

input terminal configuration

input terminal configuration specifies the input terminal configuration for the channel.

Name Description
default

At run time, NI-DAQmx chooses the default terminal configuration for the channel.

Differential

Differential mode.

NRSE

Non-referenced single-ended mode.

Pseudodifferential

Pseudodifferential mode.

RSE

Referenced single-ended mode.

datatype_icon

custom scale name

custom scale name specifies the name of a custom scale for the channel.

datatype_icon

shunt resistor location

shunt resistor location specifies the location of the shunt resistor. For devices with built-in shunt resistors, specify the location as Internal. For devices that do not have built-in shunt resistors, you must attach an external one. When you have attached an external one, set this input to External, and use the external shunt resistor value input to specify the value of the resistor.

Name Description
default

NI-DAQmx selects Internal for devices with an internal shunt resistor. NI-DAQmx selects External for devices without an internal shunt resistor.

External

Use a shunt resistor external to the device. You must use the external shunt resistor value input to specify the value of the shunt resistor.

Internal

Use the built-in shunt resistor of the device.

datatype_icon

external shunt resistor value

external shunt resistor value specifies in ohms the resistance of an external shunt resistor.

datatype_icon

task out

task out is a reference to the task after this node runs. The task contains any newly created virtual channels. If you did not wire a value to task in, NI-DAQmx automatically creates the task this output refers to.

datatype_icon

error out

error out contains error information. If error in indicates that an error occurred before this node ran, error out contains the same error information. Otherwise, error out describes the error status that this node produces.

Where This Node Can Run:

Desktop OS: Windows

FPGA: LabVIEW NXG does not support FPGA devices

Web Server: Not supported in VIs that run in a web application


Recently Viewed Topics