Specifies the type of trigger to use to pause a task.

Data type: datatype_icon

Name Value Description
Analog Level 10101 Pause the measurement or generation while an analog signal is above or below a level.
Analog Window 10103 Pause the measurement or generation while an analog signal is either inside or outside of a range of values.
Digital Level 10152 Pause the measurement or generation while a digital signal is at either a high or low state.
Digital Pattern 10398 Pause the measurement or generation while digital physical channels either match or do not match a digital pattern.
None 10230 Do not pause the measurement or generation.

Long Name: Trigger:More:Pause:Trigger Type

Class: DAQmx Task

Permissions: Read/Write

Where This Property Is Available:

Desktop OS: Windows

FPGA:

Web Server: Not supported in VIs that run in a web application