Table Of Contents

CI.MaxMeasPeriod

Version:
    Last Modified: May 21, 2018

    Specifies the maximum period (in seconds) in which the device will recognize signals. For frequency measurements, a signal with a higher period than the one set in this property will return 0 Hz. For duty cycle, the device will return 0 or 1 depending on the state of the line during the max defined period of time. Period measurements will return NaN. Pulse width measurement will return zero.

    Data type: datatype_icon

    Long Name: Channel:Counter Input:General Properties:More:Advanced:Maximum Measurable Period

    Class: DAQmx Task

    Permissions: Read/Write

    Where This Property Is Available:

    Desktop OS: Windows

    FPGA:

    Web Server: Not supported in VIs that run in a web application