Table Of Contents

DAQmx Write (Multiple Channels) (G Dataflow)

Last Modified: September 18, 2017

Writes a single sample of Boolean values to each channel in a task that contains multiple digital output channels. Each channel in the task can contain only one digital line.

connector_pane_image
datatype_icon

task in

task in is the name of the task that the operation applies.

datatype_icon

error in

error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

datatype_icon

data

data contains a 1D array of Boolean samples to write to the task. Each element of the array corresponds to a channel in the task.

datatype_icon

timeout

timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the node returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the node waits indefinitely.

If you set timeout to 0, the node tries once to read the requested samples and returns an error if it is unable to.

datatype_icon

auto start

auto start specifies if this node automatically starts the task if you did not explicitly start it with the DAQmx Start Task node.

datatype_icon

task out

task out is a reference to the task after this node runs.

datatype_icon

error out

error out contains error information. This output provides standard error out functionality.

datatype_icon

number of samples written per channel

number of samples written per channel is the actual number of samples this node successfully wrote to each channel in the task.

Where This Node Can Run:

Desktop OS: Windows

FPGA: LabVIEW NXG does not support FPGA devices

Web Server: Not supported in VIs that run in a web application


Recently Viewed Topics