Table Of Contents

DAQmx Write (Single Sample) (G Dataflow)

Version:
    Last Modified: February 6, 2017

    Writes a new pulse frequency and duty cycle to a counter output task that contains a single channel.

    connector_pane_image
    datatype_icon

    task in

    task in is the name of the task that the operation applies.

    datatype_icon

    error in

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

    datatype_icon

    frequency

    frequency specifies at what frequency to generate pulses.

    datatype_icon

    duty cycle

    duty cycle is the width of the pulse divided by the pulse period. NI-DAQmx uses this ratio combined with frequency to determine pulse width and the interval between pulses.

    datatype_icon

    timeout

    timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the node returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the node waits indefinitely.

    If you set timeout to 0, the node tries once to read the requested samples and returns an error if it is unable to.

    datatype_icon

    auto start

    auto start specifies if this node automatically starts the task if you did not explicitly start it with the DAQmx Start Task node.

    datatype_icon

    task out

    task out is a reference to the task after this node runs.

    datatype_icon

    error out

    error out contains error information. This output provides standard error out functionality.

    datatype_icon

    number of samples written per channel

    number of samples written per channel is the actual number of samples this node successfully wrote to each channel in the task.