    Configures when the DAQ device transfers data to a peripheral device, using an imported sample clock to control burst handshake timing.

    connector_pane_image
    datatype_icon

    task in

    task in is the name of the task that the operation applies.

    datatype_icon

    sample clock rate

    sample clock rate specifies in hertz the rate of the Sample Clock.

    datatype_icon

    sample clock source

    sample clock source specifies the source terminal of the Sample Clock. Leave this input unwired to use the default onboard clock of the device.

    datatype_icon

    sample clock active edge

    sample clock active edge specifies on which edges of Sample Clock pulses to acquire or generate samples.

    Name Description
    Falling

    Acquire or generate samples on falling edges of the Sample Clock.

    Rising

    Acquire or generate samples on rising edges of the Sample Clock.

    datatype_icon

    error in

    error in describes error conditions that occur before this node runs. This input provides standard 'error in' functionality.

    datatype_icon

    sample mode

    sample mode specifies if the task acquires, or generates samples continuously, or if it acquires or generates a finite number of samples.

    Name Description
    Continuous Samples

    Acquire or generate samples until DAQmx Stop Task runs.

    Finite Samples

    Acquire or generate a finite number of samples.

    Hardware Timed Single Point

    Acquire or generate samples continuously using hardware timing without a buffer. Hardware timed single point sample mode is supported only for the sample clock and change detection timing types.

    datatype_icon

    samples per channel

    samples per channel specifies the number of samples to acquire, or generate for each channel in the task, if sample mode is Finite Samples. If sample mode is Continuous Samples, NI-DAQmx uses this value to determine the buffer size. This node returns an error if the specified value is negative.

    datatype_icon

    pause when

    pause when specifies whether the task pauses while the trigger signal is high or low.

    Name Description
    High

    Pause the task while the trigger signal is high.

    Low

    Pause the task while the trigger signal is low.

    datatype_icon

    ready for transfer event active level

    ready for transfer event active level specifies the polarity of the Ready for Transfer Event.

    Name Description
    Active High

    Active high.

    Active Low

    Active low.

    datatype_icon

    task out

    task out is a reference to the task after this node runs.

    datatype_icon

    error out

    error out contains error information. If error in indicates that an error occurred before this node ran, error out contains the same error information. Otherwise, error out describes the error status that this node produces.

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: LabVIEW NXG does not support FPGA devices


    Recently Viewed Topics