Table Of Contents

DAQmx Timing (Burst Export Clock) (G Dataflow)

Last Modified: February 6, 2017

Configures when the DAQ device transfers data to a peripheral device, using the onboard Sample Clock of the DAQ device to control burst handshake timing, and exporting that clock for use by the peripheral device.

connector_pane_image
datatype_icon

task in

task in is the name of the task that the operation applies.

datatype_icon

sample clock rate

sample clock rate specifies in hertz the rate of the Sample Clock.

datatype_icon

sample clock output terminal

sample clock output terminal specifies the terminal to which to export the Sample Clock.

datatype_icon

sample clock pulse polarity

sample clock pulse polarity specifies the polarity of the exported Sample Clock.

Name Description
Active High

Active high.

Active Low

Active low.

datatype_icon

error in

error in describes error conditions that occur before this node runs. This input provides standard 'error in' functionality.

datatype_icon

sample mode

sample mode specifies if the task acquires, or generates samples continuously, or if it acquires or generates a finite number of samples.

Name Description
Continuous Samples

Acquire or generate samples until DAQmx Stop Task runs.

Finite Samples

Acquire or generate a finite number of samples.

Hardware Timed Single Point

Acquire or generate samples continuously using hardware timing without a buffer. Hardware timed single point sample mode is supported only for the sample clock and change detection timing types.

datatype_icon

samples per channel

samples per channel specifies the number of samples to acquire, or generate for each channel in the task, if sample mode is Finite Samples. If sample mode is Continuous Samples, NI-DAQmx uses this value to determine the buffer size. This node returns an error if the specified value is negative.

datatype_icon

pause when

pause when specifies whether the task pauses while the trigger signal is high or low.

Name Description
High

Pause the task while the trigger signal is high.

Low

Pause the task while the trigger signal is low.

datatype_icon

ready for transfer event active level

ready for transfer event active level specifies the polarity of the Ready for Transfer Event.

Name Description
Active High

Active high.

Active Low

Active low.

datatype_icon

task out

task out is a reference to the task after this node runs.

datatype_icon

error out

error out contains error information. If error in indicates that an error occurred before this node ran, error out contains the same error information. Otherwise, error out describes the error status that this node produces.

Where This Node Can Run:

Desktop OS: Windows

FPGA: LabVIEW NXG does not support FPGA devices


Recently Viewed Topics