Table Of Contents

DAQmx Get Power Up States (Analog) (G Dataflow)

Version:
    Last Modified: February 6, 2017

    Gets the power up states for analog physical channels.

    connector_pane_image
    datatype_icon

    dev in

    dev in is the name as configured in MAX of the device to which this operation applies. A DAQmx device name constant lists all devices installed in the system.

    datatype_icon

    error in

    error in describes error conditions that occur before this node runs. This input provides standard 'error in' functionality.

    datatype_icon

    dev out

    dev out is the name of the device the operation applied to.

    datatype_icon

    voltage power up states

    voltage power up states contains the physical channels and power up states set. Each element of the array contains a physical channel and the power up state set for that physical channel. Voltage power up states are set only for physical channels that support voltage output.

    datatype_icon

    physical channel

    physical channel is the physical channel that was modified. The DAQmx physical channel constant lists all physical channels for devices installed in the system.

    datatype_icon

    value

    value is the power up state set for the physical channel specified with the physical channel output.

    datatype_icon

    current power up states

    current power up states contains the physical channels and power up states set. Each element of the array contains a physical channel and the power up state set for that physical channel. Power up states are set only for physical channels that support current output.

    datatype_icon

    physical channel

    physical channel is the physical channel that was modified. The DAQmx physical channel constant lists all physical channels for devices installed in the system.

    datatype_icon

    value

    value is the power up state set for the physical channel specified with the physical channel output.

    datatype_icon

    error out

    error out contains error information. If error in indicates that an error occurred before this node ran, error out contains the same error information. Otherwise, error out describes the error status that this node produces.

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: LabVIEW NXG does not support FPGA devices


    Recently Viewed Topics