Table Of Contents

DAQmx Get Power Up States (Analog (670x)) (G Dataflow)

Version:
    Last Modified: February 6, 2017

    Gets the power up states for analog physical channels.

    connector_pane_image
    datatype_icon

    physical channels

    physical channels is the digital line or port to modify. You cannot modify dedicated digital input lines. The DAQmx physical channel constant lists all lines and ports for devices installed in the system.

    You also can wire a string that contains a list or range of digital lines or ports to this input. If you have an array of lines or ports, use DAQmx Flatten Channel String to convert the array to a list.

    datatype_icon

    error in

    error in describes error conditions that occur before this node runs. This input provides standard 'error in' functionality.

    datatype_icon

    analog power up states

    analog power up states contains the physical channels and power up states. Each element of the array contains a physical channel and the power up state for that physical channel.

    datatype_icon

    physical channel

    physical channel is the physical channel that was modified. The DAQmx physical channel constant lists all physical channels for devices installed in the system.

    datatype_icon

    output type

    output type indicates the output type of the physical channel.

    Name Description
    Voltage

    Voltage output.

    Current

    Current output.

    High-Impedance

    High-impedance state.

    datatype_icon

    value

    value is the power up state set for the physical channel specified with the physical channel output.

    datatype_icon

    error out

    error out contains error information. If error in indicates that an error occurred before this node ran, error out contains the same error information. Otherwise, error out describes the error status that this node produces.

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: LabVIEW NXG does not support FPGA devices