Table Of Contents

DAQmx Create TEDS Virtual Channel (G Dataflow)

Version:
    Last Modified: February 6, 2017

    Creates a virtual channel, or set of virtual channels, and adds them to a task. You must configure the physical channel(s) with TEDS information to use this node.

    If you use this node within a loop without specifying a task in, the software creates a new task in each iteration of the loop. Use the DAQmx Clear Task node within the loop, after you are finished with the task, to avoid allocating unnecessary memory.

    The DAQmx Channel properties include additional channel configuration options.

    node_icon
    Creates channel(s) that use an accelerometer to measure acceleration. You must configure the physical channel(s) with TEDS information to use this VI.
    node_icon
    Creates channel(s) that measure a Wheatstone bridge. You must configure the physical channel(s) with TEDS information to use this VI. Use this instance with bridge-based sensors that measure phenomena other than strain, force, pressure, or torque, or that scale data to physical units NI-DAQmx does not support.
    node_icon
    Creates channel(s) to measure current. You must configure the physical channel(s) with TEDS information to use this VI.
    node_icon
    Creates channel(s) that use a Wheatstone bridge to measure force or load. You must configure the physical channel(s) with TEDS information to use this VI. NI-DAQmx scales electrical values to physical values according to that TEDS information.
    node_icon
    Creates channel(s) that use an IEPE force sensor to measure force or load. You must configure the physical channel(s) with TEDS information to use this VI.
    node_icon
    Creates channel(s) that use an LVDT to measure linear position. You must configure the physical channel(s) with TEDS information to use this VI.
    node_icon
    Creates channel(s) that use an RVDT to measure angular position. You must configure the physical channel(s) with TEDS information to use this VI.
    node_icon
    Creates channel(s) that use a Wheatstone bridge to measure pressure. You must configure the physical channel(s) with TEDS information to use this VI. NI-DAQmx scales electrical values to physical values according to that TEDS information.
    node_icon
    Creates channel(s) to measure resistance. You must configure the physical channel(s) with TEDS information to use this VI.
    node_icon
    Creates channel(s) that use a microphone to measure sound pressure. You must configure the physical channel(s) with TEDS information to use this VI.
    node_icon
    Creates channel(s) to measure strain. You must configure the physical channel(s) with TEDS information to use this VI.
    node_icon
    Creates channel(s) that use an RTD to measure temperature. You must configure the physical channel(s) with TEDS information to use this VI.
    node_icon
    Creates channel(s) that use a thermistor to measure temperature. Use this instance when the thermistor requires current excitation. You must configure the physical channel(s) with TEDS information to use this VI.
    node_icon
    Creates channel(s) that use a thermistor to measure temperature. Use this instance when the thermistor requires voltage excitation. You must configure the physical channel(s) with TEDS information to use this VI.
    node_icon
    Creates channel(s) that use a thermocouple to measure temperature. You must configure the physical channel(s) with TEDS information to use this VI.
    node_icon
    Creates channel(s) that use a Wheatstone bridge to measure torque. You must configure the physical channel(s) with TEDS information to use this VI. NI-DAQmx scales electrical values to physical values according to that TEDS information.
    node_icon
    Creates channel(s) to measure voltage. You must configure the physical channel(s) with TEDS information to use this VI. If the measurement requires the use of internal excitation or you need excitation to scale the voltage, use the instance of this VI.
    node_icon
    Creates channel(s) to measure voltage. Use this instance for custom sensors that require excitation. You can use the excitation to scale the measurement. You must configure the physical channel(s) with TEDS information to use this VI.