DAQmx Create Virtual Channel (Counter Input » Semi Period) (G Dataflow)

Last Modified: February 6, 2017

Creates a channel to measure the time between state transitions of a digital signal. With the exception of devices that support multi-counter tasks, you can create only one counter input channel at a time with this node because a task can contain only one counter input channel. To read from multiple counters simultaneously, use a separate task for each counter. Connect the input signal to the default input terminal of the counter unless you select a different input terminal.

connector_pane_image
datatype_icon

task in

task in specifies the task to which to add the virtual channels this node creates. If you do not specify a task, NI-DAQmx creates a task for you, and adds the virtual channels this node creates to that task.

datatype_icon

counter

counter specifies the name of the counter to use to create the virtual channel. The DAQmx physical channel constant lists all physical channels, including counters, for devices installed in the system.

datatype_icon

name to assign

name to assign specifies a name to assign to the virtual channel this node creates. If you do not wire a value to this input, NI-DAQmx uses the physical channel name as the virtual channel name.

If you use this input to provide your own names for the virtual channels, you must use the names when you refer to these channels in other NI-DAQmx nodes, such as the source input of the DAQmx Trigger node.

If you create multiple virtual channels with one DAQmx Create Virtual Channel node, you can specify a comma-separated list of names to assign to the virtual channels. If you provide fewer names than the number of virtual channels you create, NI-DAQmx automatically assigns names to the virtual channels.

datatype_icon

units

units specifies the units to use to return time or period measurements.

Name Description
From Custom Scale

Units a custom scale specifies. If you select this value, you must wire a custom scale name to the custom scale name input.

Seconds

Seconds.

Ticks

Timebase ticks.

datatype_icon

error in

error in describes error conditions that occur before this node runs. This input provides standard 'error in' functionality.

datatype_icon

measurement range

measurement range specifies the minimum and maximum values you expect to measure.

datatype_icon

maximum value

maximum value specifies in units the maximum value you expect to measure.

datatype_icon

minimum value

minimum value specifies in units the minimum value you expect to measure.

datatype_icon

custom scale name

custom scale name specifies the name of a custom scale for the channel. If you want the channel to use a custom scale, wire the name of the custom scale to this input, and set units to From Custom Scale.

datatype_icon

task out

task out is a reference to the task after this node runs. The task contains any newly created virtual channels. If you did not wire a value to task in, NI-DAQmx automatically creates the task this output refers to.

datatype_icon

error out

error out contains error information. If error in indicates that an error occurred before this node ran, error out contains the same error information. Otherwise, error out describes the error status that this node produces.