DAQmx Create TEDS Virtual Channel (DAQmx Create Channel (TEDS-AI-Voltage-Custom with Excitation)) (G Dataflow)

Version:
    Last Modified: February 6, 2017

    Creates channel(s) to measure voltage. Use this instance for custom sensors that require excitation. You can use the excitation to scale the measurement. You must configure the physical channel(s) with TEDS information to use this VI.

    connector_pane_image
    datatype_icon

    task in

    task in specifies the task to which to add the virtual channels this node creates. If you do not specify a task, NI-DAQmx creates a task for you, and adds the virtual channels this node creates to that task.

    datatype_icon

    physical channels

    physical channels specifies the names of the physical channels to use to create virtual channels. The DAQmx physical channel constant lists all physical channels on devices and modules installed in the system.

    You can also wire a string that contains a list, or range of physical channels, to this input. If you have an array of physical channels, use the DAQmx Flatten Channel String node to convert the array to a list.

    datatype_icon

    name to assign

    name to assign specifies a name to assign to the virtual channel this node creates. If you do not wire a value to this input, NI-DAQmx uses the physical channel name as the virtual channel name.

    If you use this input to provide your own names for the virtual channels, you must use the names when you refer to these channels in other NI-DAQmx nodes, such as the source input of the DAQmx Trigger node.

    If you create multiple virtual channels with one DAQmx Create Virtual Channel node, you can specify a comma-separated list of names to assign to the virtual channels. If you provide fewer names than the number of virtual channels you create, NI-DAQmx automatically assigns names to the virtual channels.

    datatype_icon

    units

    units specifies the units to use to return measurements.

    Name Description
    From Custom Scale

    Units a custom scale specifies. If you select this value, you must wire a custom scale name to the custom scale name input.

    From TEDS

    Units defined by TEDS information associated with the channel.

    datatype_icon

    error in

    error in describes error conditions that occur before this node runs. This input provides standard 'error in' functionality.

    datatype_icon

    measurement range

    measurement range specifies the minimum and maximum values you expect to measure.

    datatype_icon

    maximum value

    maximum value specifies in units the maximum value you expect to measure.

    datatype_icon

    minimum value

    minimum value specifies in units the minimum value you expect to measure.

    datatype_icon

    input terminal configuration

    input terminal configuration specifies the input terminal configuration for the channel.

    Name Description
    default

    At run time, NI-DAQmx chooses the default terminal configuration for the channel.

    Differential

    Differential mode.

    NRSE

    Non-referenced single-ended mode.

    Pseudodifferential

    Pseudodifferential mode.

    RSE

    Referenced single-ended mode.

    datatype_icon

    custom scale name

    custom scale name specifies the name of a custom scale for the channel. If you want the channel to use a custom scale, wire the name of the custom scale to this input, and set units to From Custom Scale.

    datatype_icon

    voltage excitation

    voltage excitation specifies the value and source of voltage excitation.

    datatype_icon

    voltage excitation source

    voltage excitation source specifies the source of excitation.

    Name Description
    External

    Use an excitation source other than the built-in excitation source of the device. If you select this value, you must use the voltage excitation value input to specify the amount of excitation.

    Internal

    Use the built-in excitation source of the device. If you select this value, you must use the voltage excitation value input to specify the amount of excitation.

    None

    Supply no excitation to the channel.

    datatype_icon

    voltage excitation value

    voltage excitation value specifies in volts the amount of excitation supplied to the sensor. Refer to the sensor documentation to determine appropriate excitation values.

    datatype_icon

    task out

    task out is a reference to the task after this node runs. The task contains any newly created virtual channels. If you did not wire a value to task in, NI-DAQmx automatically creates the task this output refers to.

    datatype_icon

    error out

    error out contains error information. If error in indicates that an error occurred before this node ran, error out contains the same error information. Otherwise, error out describes the error status that this node produces.