Table Of Contents

DAQmx Get Possible SC Express Calibration Accessory Connections (G Dataflow)

Version:
    Last Modified: February 6, 2017

    Gets the available connections on an SC Express accessory for the specified physical channel(s).

    Connections specify how channels on the SC Express accessory should be configured. The resulting configuration could connect channels to a particular external signal or an onboard terminal.

    connector_pane_image
    datatype_icon

    dev in

    dev in specifies the name of the SC Express accessory to use.

    datatype_icon

    physical channels

    physical channels specifies the names of the SC Express physical channel(s) to use. You can use a list or range of physical channels with this input.

    datatype_icon

    error in

    error in describes error conditions that occur before this node runs. This input provides standard 'error in' functionality.

    datatype_icon

    dev out

    dev out is the name of the device the operation applied to.

    datatype_icon

    connections

    connections contains the available connections for your accessory.

    datatype_icon

    error out

    error out contains error information. If error in indicates that an error occurred before this node ran, error out contains the same error information. Otherwise, error out describes the error status that this node produces.

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: LabVIEW NXG does not support FPGA devices


    Recently Viewed Topics