Table Of Contents

MT Reed Solomon Symbol Decode (MT RS Symbol Decoder (normal)) (G Dataflow)

Version:
    Last Modified: February 7, 2018

    Decodes a Reed-Solomon (RS) encoded symbol stream in normal format.

    RS codes are specialized Bose-Chaudhari-Hocquenghem (BCH) codes in which the code elements are drawn from the Galois field, GF(2m). RS codes are extremely powerful at burst error correction. The operations involved in Reed-Solomon encoding and decoding are performed in the GF(2m). The RS encoder operates on code words that are symbols or groups of bits. The parameters code word length (n), symbols and data word length (k), symbols are specified in terms of symbols. Each symbol represents a group of Log2(n+1) bits.

    The normal RS (n,k,t) code consists of values of n of the form n = 2 m -1, where valid values of m are 2 to 16, inclusive. For example, set n = 255, k = 233 to produce a RS (255,233,11) code. This code has an error-correcting capacity of 11 RS symbols.

    connector_pane_image
    datatype_icon

    input symbols

    The array of integer symbols to be decoded using the Reed-Solomon (RS) decoding scheme. Use the RS symbol encoder nodes to generate the integer symbols required for this parameter.

    spd-note-note
    Note  

    The RS decoder is a block decoder, which means that it operates on a block of n integers. To ensure that the output symbols stream corresponds to the entire input symbols array, set the length L of input symbols to be an integer multiple of n symbols. If the length L is not a multiple of n symbols, the last L modulo n symbols are buffered inside the decoder. These symbols are added to the incoming input symbols stream at the beginning of the next iteration if reset? is set to FALSE.

    datatype_icon

    code word length (n), symbols

    The length of the Reed-Solomon (RS) code word. Each RS symbol represents log 2 (n+1) bits.

    Default: 7

    datatype_icon

    data word length (k), symbols

    The length of the Reed-Solomon (RS) data word. Each RS symbol represents log 2 (n+1) bits.

    Default: 3

    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    modulation session

    The modulation session for configuring selected properties of the Modulation nodes. Use this parameter to configure the advanced properties in the MT RS Symbol Encoder nodes. If MT RS Symbol Encoder is called with an uninitialized modulation session, the node returns an error.

    Default: 0

    datatype_icon

    reset?

    A Boolean that determines whether the internal state of the decoder is cleared.

    TRUE Clears any buffered bits from previous iterations. Also initializes the Galois field structure corresponding to the Reed-Solomon n, k values.
    FALSE Continues decoding from the previous iteration. Any buffered bits from the previous iteration are added to the beginning of the input bit stream prior to decoding.

    Default: TRUE

    datatype_icon

    output symbols

    The decoded integer symbol stream. Wire this parameter to MT UnPack Bits to recover the message bits that comprise the transmitted message data.

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: Not supported

    Web Server: Not supported in VIs that run in a web application