Table Of Contents

MT Modulate PM (G Dataflow)

Version:
    Last Modified: February 7, 2018

    Performs phase modulation (PM) on an RF carrier wave according to the baseband information signal specified by the message signal parameter. This node performs signal processing on data and operates independently of your hardware settings. You can use this node in both simulated and hardware-equipped applications.

    connector_pane_image
    datatype_icon

    message signal

    Message signal used to modulate the carrier wave.

    datatype_icon

    phase deviation

    The maximum desired phase deviation, in degrees, of the phase-modulated signal returned in the PM modulated waveform parameter.

    Default: 1 degree

    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    PM modulated waveform

    The baseband signal data and the complex envelope of the phase-modulated signal.

    datatype_icon

    t0

    The trigger (start) time of the signal data.

    datatype_icon

    dt

    Time interval between data points in the signal data.

    datatype_icon

    Y

    The complex-valued time-domain data array. The real and imaginary parts of this complex data array correspond to the in-phase (I) and quadrature-phase (Q) data, respectively.

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Phase-Modulated Wave Formula

    The output phase-modulated wave is described by the equation:

    P M = e i ( 2 π p h a s e D e v i a t i o n 360 ( m e s s a g e S i g n a l ) + ( c a r r i e r P h a s e ) )

    This node sets carrierPhase in the preceding equation to 0. To adjust the carrier phase, use the initial phase parameter of MT Upconvert Baseband (Real) or MT Upconvert Baseband (Complex).