Table Of Contents

Close Reference (G Dataflow)

Version:
    Last Modified: September 18, 2017

    Closes a reference associated with an open VI, component, open application instance, or .NET or ActiveX object.

    connector_pane_image
    datatype_icon

    reference

    The reference associated with an open VI, VI object, open application instance, or .NET or ActiveX object. This terminal also accepts a 1D array of references.

    datatype_icon

    error in

    Error conditions that occur before this node runs. Unlike most nodes, this node runs normally even if an error occurs before this node runs.

    Default: no error

    datatype_icon

    error out

    Information about errors or warnings that occurred during or before the execution of this node.

    Releasing a VI Reference from Memory

    When you create a reference to a VI, the VI stays in memory until you close the reference and the VI meets the following conditions:

    • There are no other open references to the VI.
    • The panel of the VI is not open.
    • The VI is not a subVI of another VI in memory.
    • The VI is not a member of an open project library.

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: This product does not support FPGA devices

    Web Server: Not supported in VIs that run in a web application


    Recently Viewed Topics