Create Gain (P) (G Dataflow)

Last Modified: December 18, 2017

Returns proportional gains of a P controller.

connector_pane_image
datatype_icon

proportional unit

Unit associated with the proportional gain.

The relationship between the available units is K = 100/PB.

This input accepts a ring or an array of rings.

Name Value Description
Gain (K) 0 Specifies that the proportional gain is expressed in terms of proportional gain (K).
Band (PB) 1 Specifies that the proportional gain is expressed in terms of proportional band (PB).

Default: Gain (K)

datatype_icon

proportional

Value of the proportional component of the controller.

This input accepts a double-precision, floating-point number or an array of double-precision, floating-point numbers.

datatype_icon

action

Action of the controller.

This input accepts a ring or an array of rings.

Name Value Description
Reverse 0 The controller is reverse-acting.
Direct 1 The controller is direct-acting.

Default: Reverse

datatype_icon

proportional gain

Proportional gain of the controller.

This output can return a double-precision, floating-point number or an array of double-precision, floating-point numbers.

Algorithm Definition

The following transfer function represents a P controller:

C ( s ) = K p

where Kp is the proportional gain.