Generates setpoint values over time in a control loop for ramp and soak types of control applications.
An array of time and setpoint value pairs that define the profile of the setpoint as a function of time.
Time values in the setpoint profile. Specify time (s) in ascending order.
Setpoint values in the setpoint profile.
Loop-cycle time or interval, in seconds, at which this node is called.
dt must be greater than zero.
Setpoint value this node calculates from setpoint profile and from the elapsed time since the first call or reinitialization of this node.
A Boolean that indicates whether the elapsed time is greater than or equal to the last defined time value in setpoint profile.
True | The elapsed time is greater than or equal to the last defined time value in setpoint profile. |
False | The elapsed time is less than the last defined time value in setpoint profile. |
Elapsed time, in seconds, since the first call of the node or since the reinitialization of the node.
Where This Node Can Run:
Desktop OS: Windows
FPGA: This product does not support FPGA devices
Web Server: Not supported in VIs that run in a web application