Table Of Contents

Set Control Value (G Dataflow)

Last Modified: January 12, 2018

Specifies the value of a named control or indicator. You can wire a value of any data type to this method.

connector_pane_image
datatype_icon

reference in

A reference to a VI.

Use Open VI Reference or Static VI Reference to obtain a valid reference for this input.

datatype_icon

control value

Value of the control or indicator you want.

datatype_icon

control name

Label for the control or indicator whose value you want.

datatype_icon

error in

Error conditions that occur before this node runs.

The node responds to this input according to standard error behavior.

Standard Error Behavior

Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

error in does not contain an error error in contains an error
If no error occurred before the node runs, the node begins execution normally.

If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

Default: No error

datatype_icon

reference out

Unchanged reference to the same VI.

datatype_icon

error out

Error information.

The node produces this output according to standard error behavior.

Standard Error Behavior

Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

error in does not contain an error error in contains an error
If no error occurred before the node runs, the node begins execution normally.

If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

Using Set Control Value

This node requires the referenced VI to have a panel. To use this node to retrieve data from an application, make sure you include the panel when you build the application.

Where This Node Can Run:

Desktop OS: Windows

FPGA: This product does not support FPGA devices

Web Server: Not supported in VIs that run in a web application


Recently Viewed Topics