Table Of Contents

Query Registry Key Info (G Dataflow)

Last Modified: March 15, 2017

Retrieves information about keys.

spd-note-caution
Caution  

Incorrectly modifying the registry can damage Windows or prevent you from starting Windows.

connector_pane_image
datatype_icon

reference in

Reference to the open registry key.

datatype_icon

error in

Error conditions that occur before this node runs.

The node responds to this input according to standard error behavior.

Standard Error Behavior

Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

error in does not contain an error error in contains an error
If no error occurred before the node runs, the node begins execution normally.

If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

Default: No error

datatype_icon

reference out

Reference to the open registry key.

datatype_icon

class

Class or object type of the key.

datatype_icon

value info

Set of parameters describing the set of values and data.

datatype_icon

numValues

Number of values under the key specified by hKey.

datatype_icon

maxValueNameLen

Length of the longest value name under the key specified by hKey.

datatype_icon

maxValueDataLen

Length of the longest datum under the key specified by hKey.

datatype_icon

error out

Error information.

The node produces this output according to standard error behavior.

Standard Error Behavior

Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

error in does not contain an error error in contains an error
If no error occurred before the node runs, the node begins execution normally.

If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.
datatype_icon

subkey info

Set of parameters describing the subkeys.

datatype_icon

numSubKeys

Number of subkeys under the key specified by hKey.

datatype_icon

maxSubKeyLen

Length of the longest subkey name under the key specified by hKey.

datatype_icon

maxSubKeyClassLen

Length of the longest class name under the key specified by hKey.

Where This Node Can Run:

Desktop OS: Windows

FPGA: This product does not support FPGA devices


Recently Viewed Topics