Table Of Contents

Scaling and Mapping (Standardize) (G Dataflow)

Version:
    Last Modified: March 31, 2017

    Standardizes a signal by using its statistical profile (mean, standard deviation) to obtain a standardized signal whose statistical profile is (0,1).

    connector_pane_image
    datatype_icon

    reset

    A Boolean that specifies whether to reset the internal state of the node.

    True Resets the internal state of the node.
    False Does not reset the internal state of the node.

    This input is available only if you wire a double-precision, floating-point number to signal.

    Default: False

    datatype_icon

    signal

    Input signal.

    This input accepts the following data types:

    • Waveform
    • 1D array of waveforms
    • Double-precision, floating-point number
    • 1D array of double-precision, floating-point numbers
    • 2D array of double-precision, floating-point numbers
    datatype_icon

    sample length

    Length of each set of data.

    The node performs computation for each set of data. sample length must be greater than zero.

    This input is available only if you wire a double-precision, floating-point number to signal.

    Default: 100

    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    standardized signal

    Result of standardizing the input signal.

    This output can return the following data types:

    • Waveform
    • 1D array of waveforms
    • 1D array of double-precision, floating-point numbers
    • 2D array of double-precision, floating-point numbers
    datatype_icon

    standard deviation

    Standard deviation of the values in the input signal.

    datatype_icon

    mean

    Average of the values in the input signal.

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: This product does not support FPGA devices


    Recently Viewed Topics