Table Of Contents

Trigger (G Dataflow)

Last Modified: March 31, 2017

Detects changes of the input signal during a control or simulation process.

connector_pane_image
datatype_icon

reset

A Boolean or a Boolean array that determines whether to set triggered to False and store the current trigger signal.

True Sets triggered to False and stores the current trigger signal.
False Does not set triggered to False or store the current trigger signal.

Default: False

datatype_icon

trigger signal

Input signal.

This input accepts a double-precision, floating-point number or an array of double-precision, floating-point numbers.

datatype_icon

trigger type

Type of changes to the input signal that sets triggered to True.

This input accepts a ring or an array of rings.

Name Value Description
rising 0 Sets triggered to True when the input signal crosses threshold on a rising slope.
falling 1 Sets triggered to True when the input signal crosses threshold on a falling slope.
either 2 Sets triggered to True when the input signal crosses threshold on either a rising or a falling slope.

Default: rising

datatype_icon

threshold

Threshold to start the measurement.

This input accepts a double-precision, floating-point number or an array of double-precision, floating-point numbers.

Default: 0

datatype_icon

triggered?

A Boolean or a Boolean array that indicates whether the last two points in trigger signal meet the conditions you set in trigger type.

True The last two points in trigger signal meet the conditions you set in trigger type.
False The last two points in trigger signal do not meet the conditions you set in trigger type.

Where This Node Can Run:

Desktop OS: Windows

FPGA: This product does not support FPGA devices


Recently Viewed Topics