Table Of Contents

Setpoint Profile (G Dataflow)

Version:
    Last Modified: March 15, 2017

    Generates setpoint values over time in a control loop for ramp and soak types of control applications.

    connector_pane_image
    datatype_icon

    reset

    A Boolean that specifies the initialization of the internal state of the node.

    True Initializes the output to setpoint profile at time t = 0.
    False Does not initialize the internal state of the node.

    Default: False

    datatype_icon

    setpoint profile

    An array of time and setpoint value pairs that define the profile of the setpoint as a function of time.

    datatype_icon

    time (s)

    Time values in the setpoint profile. Specify time (s) in ascending order.

    datatype_icon

    setpoint

    Setpoint values in the setpoint profile.

    datatype_icon

    dt

    Loop-cycle time or interval, in seconds, at which this node is called.

    dt must be greater than zero.

    datatype_icon

    setpoint

    Setpoint value this node calculates from setpoint profile and from the elapsed time since the first call or reinitialization of this node.

    datatype_icon

    profile complete?

    A Boolean that indicates whether the elapsed time is greater than or equal to the last defined time value in setpoint profile.

    True The elapsed time is greater than or equal to the last defined time value in setpoint profile.
    False The elapsed time is less than the last defined time value in setpoint profile.
    datatype_icon

    elapsed time

    Elapsed time, in seconds, since the first call of the node or since the reinitialization of the node.